background image

w w w.asekopool.com

ASIN AQUA

ASIN AQUA 

Net

CLF, REDOX, DOSE

CLF, REDOX, DOSE

USER‘S MANUAL

EN

Summary of Contents for ASIN AQUA

Page 1: ...www asekopool com ASIN AQUA ASIN AQUA Net CLF REDOX DOSE CLF REDOX DOSE USER S MANUAL EN...

Page 2: ...chemical agents Potential consequence Injury heavy material damage Design your installation such that uncontrolled dosage is not possible in the event of a probe failure or other errors and or such th...

Page 3: ...is wrong If disinfection is enabled before the pH value is stable in the ideal range of 7 0 to 7 4 then it may lead to heavy overdosing of chlorine or bromine Potential consequence Injury heavy materi...

Page 4: ...on valve 2 pcs 12005 Suction tube weight 2 pcs 12023 Thermometer holder 1 pcs 12044 only for ASIN AQUA Net PE Tube 1 4 6 35 mm transparent 12008 Wrench socket for probes 13046 CLF probe 12052 or Redox...

Page 5: ...pH MINUS 12130 pH MINUS 12130 CHLOR PURE 12075 CHLOR PURE 12075 ASEKO original chemical solution Inserting DN50 plug 1 4 threaded for easy installation 12134 pH 7 00 Bu er 12065 Redox Bu er 12063 Pool...

Page 6: ...EN 6 ASIN AQUA ASIN AQUA CLF 12001 ASIN AQUA Redox 12144 ASIN AQUA Dose 12022 ASIN AQUA Net CLF 12036 ASIN AQUA Net Redox 12035 ASIN AQUA Net Dose 12034...

Page 7: ...ent Chlorine control and dosing Highly e ective disinfection treatment of pool water for public and private pools Extraordinary precise measuring of chlorine content in the pool water by ASEKO CLF fre...

Page 8: ...f injection valves from peristaltic ASIN AQUA pumps must not exceed 8 m Vertical distance between ASIN AQUA and the bottom of the tanks must not exceed a distance of 2 m WARNING The temperature at the...

Page 9: ...ft Tighten by hand or with the included plastic probe wrench Connect the connector marked in yellow Carefully insert the pH probe into the well on the right Tighten by hand or with the included plasti...

Page 10: ...EN 10 ASIN AQUA Net MEASURED WATER DRAINAGE OL TO POOL Heating FROM POOL POOL Pump Pump MEASURED WATER SUPPLY SUPPLY INLET OUTPUT Coagulation mixer Besgo Filtration Thermometer 1 2 3 4...

Page 11: ...he Speed t tting and then pull on the hose to secure DISCONNECT push and hold the Speed t round collet CT push and hold the Speed t round collet and pull out the connecting pipe INLET of the measured...

Page 12: ...EN 12 Max 8 m Max 8 m Max 8 m Max 8 m Max 2 m ASIN AQUA Net CHLOR PURE pH MINUS 1 2 3 4 OL TO POOL Heating FROM POOL POOL Pump Pump Coagulation mixer Besgo Filtration Thermometer...

Page 13: ...to the bottom of the canister Place the suction basket at the end of the pipe PUMP CONNECTION connect the suction of the pump on the left to the canister connect the pump discharge on the right to th...

Page 14: ...appear Disconnection from the mains Disconnect the ASIN AQUA Net mains cable from the 230 V 50 Hz socket outlet RCD Timer Current protector 30 mA 230 V 50 Hz 230 V 50 Hz Filter pump The mains socket...

Page 15: ...lockage and air bubbles in the PE tube Check tightness of all the connections Liquid must reach spraying and subsequently the tube If bubbles occur here the pump draws air in Repair the connection dis...

Page 16: ...nter the setting of the required chlorine value in pool water Required value Water temperature Help mV output signal from the CLF probe Settings Measured value The disinfection pump doses Decrease val...

Page 17: ...es in ASIN AQUA Pool volume To ensure the correct function of ASIN AQUA Net enter the correct volume of your Calculate your pool volume in m3 Length L times width W times depth D is volume V L W D V E...

Page 18: ...chlorination of pool water with Super CHLOR inorganic active chlorine without stabilizers Follow the instructions on the packaging 1 kg 80 m Choosing the disinfection probe 1 CLF free chlorine probe F...

Page 19: ...s higher wait till the chlorine concentration in the water drops down 5 Open the water supply to the probes The No water supply to the probes noti cation will disappear from the ASIN AQUA display 6 pH...

Page 20: ...oncentration of chlorine in pool water BELOWthe required value shown on the ASIN AQUA Net display increase the required value over the current setting by 0 1 by 0 2 mg l max regardless of the required...

Page 21: ...lorimeter or Pool Tester to measure the chlorine value of the pool water sample If the chlorine value in pool water is ADEQUATE your ASIN AQUA Net is prepared to maintain the required concentration of...

Page 22: ...e water supply to the probes must be open Measure the pH value directly in pool water using a colorimeter or Pool Tester Then enter this value into ASIN AQUA Net on the pH Probe Calibration screen Cal...

Page 23: ...LIBRATION menu Calibration is not necessary if the di erence between the photometer ary if the di erence between the photometer measured value and the value shown on the display is less than 0 2 mg li...

Page 24: ...cal damage The redox probe naturally ages so its sensitivity but it should never exceed the limit tolerance 12 At the bu er test 475 mV it should not measure less than 420 mV Probe response to positiv...

Page 25: ...lace the cover cassette back on ASIN AQUA Net and turn it clockwise to lock it Use new nuts which are part of the replacement hose set for connection of the PE tube Injection Valve Maintenance On a re...

Page 26: ...t access you can use the data transmission over the mobile network Connect the ASIN AQUA Net to your mobile network router via LAN cable Wi connection If you install the ASIN AQUA Net in place where i...

Page 27: ...EN 27 230 V LAN INTERNET Home network LTE LTE Router LTE Router Router Router Router Wi extender Powerline via 230 V socket outlet INTERNET INTERNET INTERNET Connect ASIN AQUA Net with LAN cabel...

Page 28: ...able After you connect the ASIN AQUA Net to the internet download the Pool Live application to your smartphone Application is available for iOS and Android operation systems Main screen after opening...

Page 29: ...l events taken actions and act levels of monitored items up to 30 days back Transparent graphic environment of chart lines is giving fast report and you can easily see interconnection of monitored val...

Page 30: ...ld up of limescale Make sure dust and dirt does not get into the containers of the chlorine and pH agent to avoid blockages and damage to the valves Check the rubber seals of your valves regularly to...

Page 31: ...sensitivity is too low Change electrolyte membrane probe pH calibration out of range 6 2 7 8 If the manually test value is outside the pH range 6 2 7 8 the following notifcation is given Adjust the pH...

Page 32: ...ers you want to see on the display Thermometer Thermometer connection 1 Install temp holder to the pipe system then insert the thermometer 2 Connect the cable 2m as standard other lengths on request i...

Page 33: ...EN 33...

Page 34: ...EN 34...

Page 35: ...EN 35...

Page 36: ...www asekopool com ASIN AQUA ASIN AQUA Net USER S MANUAL EN...

Reviews: