104
ACK-E-2009
Electrical Data
Electrical Data
Electrical Data - Cooling Only (R22)
MODEL
INDOOR UNIT
ACK 20E
ACK 25E
OUTDOOR UNIT
ALC 20C
ALC 25C
INDOOR MOTOR
INSULATION GRADE
CLASS B
CLASS B
POWER SOURCE
V/Ph/Hz
220 - 240 / 1 / 50
220 - 240 / 1 / 50
RATED INPUT POWER
W
89
103
RATED RUNNING CURRENT
A
0.40
0.45
MOTOR OUTPUT
W
20
30
POLES
6
6
OUTDOOR MOTOR
INSULATION GRADE
CLASS B
CLASS B
POWER SOURCE
V/Ph/Hz
220 - 240 / 1 / 50
220 - 240 / 1 / 50
RATED INPUT POWER
W
114
134
RATED RUNNING CURRENT
A
0.53
0.59
MOTOR OUTPUT
W
42
64
POLES
6
6
COMPRESSOR
INSULATION GRADE
CLASS E
CLASS E
POWER SOURCE
V/Ph/Hz
220 - 240 / 1 / 50
220 - 240 / 1 / 50
CAPACITOR
μ
F
50
50
RATED INPUT POWER
W
1757
2303
RATED RUNNING CURRENT
A
7.9
10.4
LOCKED ROTOR AMP
A
35 / 39 (220 / 240)
52
1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.
2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151.
MODEL
INDOOR UNIT
ACK 28E
OUTDOOR UNIT
ALC 28C
INDOOR MOTOR
INSULATION GRADE
CLASS B
POWER SOURCE
V/Ph/Hz
220 - 240 / 1 / 50
RATED INPUT POWER
W
152
RATED RUNNING CURRENT
A
0.57
MOTOR OUTPUT
W
50
POLES
6
OUTDOOR MOTOR
INSULATION GRADE
CLASS B
POWER SOURCE
V/Ph/Hz
220 - 240 / 1 / 50
RATED INPUT POWER
W
142
RATED RUNNING CURRENT
A
0.62
MOTOR OUTPUT
W
75
POLES
6
COMPRESSOR
INSULATION GRADE
CLASS E
POWER SOURCE
V/Ph/Hz
220 - 240 / 1 / 50
CAPACITOR
μ
F
60
RATED INPUT POWER
W
2426
RATED RUNNING CURRENT
A
11.0
LOCKED ROTOR AMP.
A
62
1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.
2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151.
10_Electrical Data_A.indd 104
10_Electrical Data_A.indd 104
4/6/2009 3:41:24 PM