106
ACK-E-2009
Electrical Data
Electrical Data - Heat Pump (R22)
MODEL
INDOOR UNIT
ACK 20ER
ACK 25ER
OUTDOOR UNIT
ALC 20CR
ALC 25CR
INDOOR MOTOR
INSULATION GRADE
CLASS B
CLASS B
POWER SOURCE
V/Ph/Hz
220 - 240 / 1 / 50
220 - 240 / 1 / 50
RATED INPUT POWER
W
89
103
RATED RUNNING CURRENT
A
0.40
0.45
MOTOR OUTPUT
W
20
30
POLES
6
6
OUTDOOR MOTOR
INSULATION GRADE
CLASS B
CLASS B
POWER SOURCE
V/Ph/Hz
220 - 240 / 1 / 50
220 - 240 / 1 / 50
RATED INPUT POWER
W
114
134
RATED RUNNING CURRENT
A
0.53
0.59
MOTOR OUTPUT
W
42
64
POLES
6
6
COMPRESSOR
INSULATION GRADE
CLASS E
CLASS E
POWER SOURCE
V/Ph/Hz
220 - 240 / 1 / 50
220 - 240 / 1 / 50
CAPACITOR
μ
F
60.0
50
RATED INPUT POWER (COOLING)
W
1757
2303
RATED INPUT POWER (HEATING)
W
1487
2073
RATED RUNNING CURRENT (COOLING)
A
7.9
10.4
RATED RUNNING CURRENT (HEATING)
A
6.7
9.40
LOCKED ROTOR AMP
A
32 / 34 (220 / 240)
52 / 56 (220 / 240)
1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.
2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151.
MODEL
INDOOR UNIT
ACK 28ER
OUTDOOR UNIT
ALC 28CR
INDOOR MOTOR
INSULATION GRADE
CLASS B
POWER SOURCE
V/Ph/Hz
220 - 240 / 1 / 50
RATED INPUT POWER
W
152
RATED RUNNING CURRENT
A
0.57
MOTOR OUTPUT
W
50
POLES
6
OUTDOOR MOTOR
INSULATION GRADE
CLASS B
POWER SOURCE
V/Ph/Hz
220 - 240 / 1 / 50
RATED INPUT POWER
W
142
RATED RUNNING CURRENT
A
0.62
MOTOR OUTPUT
W
75
POLES
6
COMPRESSOR
INSULATION GRADE
CLASS E
POWER SOURCE
V/Ph/Hz
220 - 240 / 1 / 50
CAPACITOR
μ
F
60
RATED INPUT POWER (COOLING)
W
2426
RATED INPUT POWER (HEATING)
W
2056
RATED RUNNING CURRENT (COOLING)
A
11.0
RATED RUNNING CURRENT (HEATING)
A
9.6
LOCKED ROTOR AMP.
A
62
1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.
2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151.
10_Electrical Data_A.indd 106