Drives and controllers
Since all drives are equipped with absolute encoders, reference runs or homefind procedures on power-on are
not needed any more. The mount knows its current position right after start-up.
Motors
ASA torque motors Ø=210mm
Controller
ASA Torque motor controller board
Feedback Sensor
high resolution optical absolute encoders
max. rotational speed
up to 10°/sec
travel angle in RA
330°
travel range in DEC
330°
Telescope control unit (TCU)
The telescope control unit is a Windows 10® computer integrated in the mount that runs the mount control
software Autoslew. The TCU can be accessed via Ethernet connection using Windows Remote Desktop® or
TeamViewer®
. A user’s computer is required for operating the telescope (not inclu
ded).
Electrical Specifications
The mount is completely powered by the power supply units inside the included mount electronics cabinet. The
maximum voltage inside the mount is 48VDC. The cabinet needs to be connected to a standard 110/230VAC
power socket or an appropriate UPS (uninterruptable power supply).
Typical power consumption during tracking: ~50-200W
Peak power consumption (acceleration, wind gusts, …): up to 500W
ASA recommends using a UPS with 1000VA or more (not included) fo
r the mount’s power supply.