background image

22

AHnet PROTOCOL

Dynamic3 family

COMMAND

DESCRIPTION

RESPONSE

FA XX 01 01 00

GO UP

FB XX 01 01 00

FA XX 01 00 00 

GO DOWN CLOSED

FB XX 01 00 00

FA XX 01 02 00

GO DOWN SCREEN UP

FB XX 01 02 00

FA XX 02 01 00

SCREEN ON

FB XX 02 01 00

FA XX 02 00 00 

SCREEN OFF

FB XX 02 00 00 

FA XX 03 01 00

DVI-A SELECTION

FB XX 03 01 00

FA XX 03 00 00

DVI 1 SELECTION

FB XX 03 00 00

FA XX 03 03 00

DVI 2 SELECTION

FB XX 03 03 00

FA XX 04 01 00

BUTTON LOCK

FB XX 04 01 00 

FA XX 04 00 00

BUTTON UN LOCK

FB XX 04 00 00

FA XX 15 00 00

ASK BACKLIGHT LEVEL

FB XX 15 00 ZZ

FA XX 15 01 ZZ

SET BACKLIGHT LEVEL

FB XX 15 01 ZZ

FA XX 16 00 00

ASK CONTRAST LEVEL

FB XX 16 00 ZZ

FA XX 16 01 ZZ

SET CONTRAST LEVEL

FB XX 16 01 ZZ

FA XX 17 00 00

ASK BRIGHTNESS LEVEL

FB XX 17 00 ZZ

FA XX 17 01 ZZ

SET BRIGHTNESS LEVEL

FB XX 17 01 ZZ

ZZ  

 Value  (0-99Dec)

XX 

AHnet address

BROADCAST XX=F8

Summary of Contents for ERT

Page 1: ...User Guide Danish craftmanship Mediterranean soul Technology Serving Design ERT IP to RS422 RS485 interface control ...

Page 2: ...LATIONS AND SECURITY 5 SAFETY INSTRUCTIONS 5 SYSTEM DESCRIPTION 7 CONTROL AND CONNECTORS 10 SYSTEM CONFIGURATION 13 AHnet ADDRESS CONFIGURATION 18 AHnet PROTOCOL 20 INFORMATION ON DISPOSAL 24 WARRANTY TERMS AND CONDITIONS 25 ...

Page 3: ...UR HOLM product Please read this installation and operating instructions carefully and keep them in a safe place for future reference We remain at your entire disposal if you have any suggestions Henrik Holm General Manager hholm albiral com ...

Page 4: ... designs are based on quality materials and the latest technology Products which endow meeting and conference rooms with silent ergonomic innovative and aesthetic solutions that integrate into the furniture hang from the walls as works of art or are used as interactive points of information The world of Arthur Holm Arthur Holm offers a selection of unique elegant versatile flexible and ergonomic p...

Page 5: ... the cable used Do not place anything on the power cord Do not locate this product where a person may walk or trip over the cord REGULATIONS AND SECURITY ATTENTION Do not disassemble or modify the device in any way This symbol warns of the presence of dangerous un insulated voltages inside some of the components of sufficient magnitude to expose people to risk of electronic shock This symbol draws...

Page 6: ...nstall the equipment in a ventilated area Avoid exposing the equipment to Rain or water Excessive heat cold or humidity Area exposed to direct sunlight Dirty areas Equipment generating strong magnetic fields Avoid placing open containers of liquid near the equipment Keep a minimum distance of 30 mm in order to have good ventilation Never place above the device any sources of flames such as lighted...

Page 7: ...ications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the s...

Page 8: ...also integrated in ERT interfaces providing an easy and direct access to the most common settings through an app and making the start up and future interventions hassle free This means there is no need to access physically the unit to set up or diagnose its installation Highlights OTAS One Touch Addressing System IP to RS422 RS485 interface ERT 60 2 AHnet inputs RS 422 ERT 30 1 AHnet input Control...

Page 9: ...sing System Remote local control and management RDM system Remote Diagnostic and Maintenance Wireless control through AHlink app ERT 60 IP to RS 422 interface to control configure and diagnose ARTHUR HOLM motorised products 2 AHnet ports RS422 RS485 to control up to 60 units Ethernet RJ45 OTAS One Touch Addressing System Remote local control and management RDM system Remote Diagnostic and Maintena...

Page 10: ...e radio signal to control the unitP using AHlink APPMMMMMMMMMMMMMMMMML DIP2 JActivates the automatic AHnet ID HHHHHHHHHHHHHconfiguration on the RS422 bus DIP3 Not used DIP4 Activates the firmware upgrade DIP5 Not used DIP6 Configures the factory IP address IP 192 168 0 128 MASK 255 255 255 0 GATEWAY 192 168 0 3 MAC 70 B3 D5 49 70 00 DIP7 Not used DIP8 Not used ...

Page 11: ... to firmware upgrade AHnet1 RJ45 RS422 port Connect the Arthur Holm or Albiral units to control using AHnet commands AHnet1 RJ45 RS422 port Connect the Arthur Holm or Albiral units to control using AHnet commands Note ERT 30 has only one AHNet RS422 port connector With and ERT 30 you can control up to 30 devices and with an ERT 60 you can control up to 60 devices using the two AHNet port connector...

Page 12: ...two RS422 ports AHnet1 or AHnet2 LED2 Change the state when the unit receives data from the local network port ETHERNET LED3 Not used LED4 Change the state when the unit send an AHnet command when the automatic AHnet ID configuration is activated DIP2 The ERT interface sends commands to the units connected on AHnet1 and AHnet2 to automatic configure the AHnet ID on each unit RF Brigths when a mobi...

Page 13: ...BUS Next figure shows a schematic connection diagram The main device controller connects to the ERT interface using the local network area Just opening the 2002 ERT port the main device controller can send AHnet commands to the ERT interface and the ERT sends the AHnet commands to the units by the RS422 ports You can connect up to 60 units to the ERT using the two RS422 RJ45 buses 30 units on each...

Page 14: ...TINGS device and power the ERT unit To control and configure the unit using AHlink APP download AHLink from App Store IOS system or from Google Play Android system The App is free Execute the AHLink on your mobile phone On App options is recommended not select Auto Connect and select Portrait on Orientation To connect to the device selects Scan for local devices ...

Page 15: ...rs and the fourth last MAC radio address Select the device to control and configure the unit Selecting the device the first page is upload on the mobile phone This page is used to check the device When the mobile APP is connected to the unit the RF LED will bright ...

Page 16: ... the AHnet address to send the command and press the function to send to AHnet RS422 BUS DynamicTalk CONTROL Send basic commands to Dynamic talk microphone family Select the AHnet address to send the command and press the function to send to AHnet RS422 BUS IP ADDRESS Shows the actual ERT IP address Note that if the DIP6 is active the unit is configured with the factory IP and this IP information ...

Page 17: ...17 SYSTEM CONFIGURATION Network configuration Change the network configuration and press NETWORK INI button to update the new network settings ...

Page 18: ... this utility it is only available on devices that has LCD screen configuration The devices that has AHnet address rotary switches don t have this functionality To activate this function activate DIP2 on SETTINGS ERT switches and power the unit The ERT will periodically send a special AHnet command to configure the AHnet address on each unit When the units receive the special AHnet address configu...

Page 19: ...19 AHnet ADDRESS CONFIGURATION ...

Page 20: ... to all the devices there are special AHnet address used as broadcast Please refer to the user manual unit as there are different family broadcast addresses BYTE 2 is the function to execute on the unit BYTE 3 first value of the function BYTE 4 second value of the function In some functions this value is not used and should be 00 Below there are some AHnet commands used to control the different fa...

Page 21: ...FB XX 03 00 00 FA XX 03 03 00 DVI 2 SELECTION FB XX 03 03 00 FA XX 04 01 00 BUTTON LOCK FB XX 04 01 00 FA XX 04 00 00 BUTTON UN LOCK FB XX 04 00 00 FA XX 15 00 00 ASK BACKLIGHT LEVEL FB XX 15 00 ZZ FA XX 15 01 ZZ SET BACKLIGHT LEVEL FB XX 15 01 ZZ FA XX 16 00 00 ASK CONTRAST LEVEL FB XX 16 00 ZZ FA XX 16 01 ZZ SET CONTRAST LEVEL FB XX 16 01 ZZ FA XX 17 00 00 ASK BRIGHTNESS LEVEL FB XX 17 00 ZZ FA ...

Page 22: ...X 03 00 00 DVI 1 SELECTION FB XX 03 00 00 FA XX 03 03 00 DVI 2 SELECTION FB XX 03 03 00 FA XX 04 01 00 BUTTON LOCK FB XX 04 01 00 FA XX 04 00 00 BUTTON UN LOCK FB XX 04 00 00 FA XX 15 00 00 ASK BACKLIGHT LEVEL FB XX 15 00 ZZ FA XX 15 01 ZZ SET BACKLIGHT LEVEL FB XX 15 01 ZZ FA XX 16 00 00 ASK CONTRAST LEVEL FB XX 16 00 ZZ FA XX 16 01 ZZ SET CONTRAST LEVEL FB XX 16 01 ZZ FA XX 17 00 00 ASK BRIGHTNE...

Page 23: ...0 GO UP FB XX 01 01 00 FA XX 01 00 00 GO DOWN FB XX 01 00 00 FA XX 02 01 00 MUTE PA FB XX 02 01 00 FA XX 02 00 00 TALK PA FB XX 02 00 00 FA XX 04 01 00 BUTTONS LOCK FB XX 04 01 00 FA XX 04 00 00 BUTTONS UNLOCK FB XX 04 00 00 ZZ Value 0 99Dec XX AHnet address BROADCAST XX F8 ...

Page 24: ...ll help save valuable resources and prevent any potential negative effects on human health and the environment which could otherwise arise from inappropriate waste handling Please contact your local authority for further details of your nearest designated collection point Penalties may be applicable for incorrect disposal of this waste in accordance with national legislation For business users in ...

Page 25: ...splay Solutions Although Albiral Display Solutions S L pays for freight and insurance costs Albiral Displays Solutions will not be responsible for any damages caused by the transportation of the goods if the customer does not inform in writing when receiving the goods 5 2 After 90 days of the purchase date the beneficiary of the warranty will pay both freight and insurance costs Albiral Display So...

Page 26: ... warranty there are no damages during transportation 8 The warranty is not valid if the beneficiary of the warranty does not include a RMA form and a copy of the purchasing invoice Please note that laws vary from country to country and the same provisions of this warranty may not apply to you If you have any doubts concerning the terms of this warranty please contact business albiral com 34 938 50...

Page 27: ...pòlit de Voltregà 08512 Barcelona Spain tel 34 93 850 23 76 23 83 fax 34 93 850 25 50 23 72 web www arthurholm com e mail marketing arthurholm com This manual can be modified without previous notice ENG October 2020 P27178ITEP P27178RUPC P27178USPC P27284DEEP P27284EPPC P27284ESEP P27284GBEP P27284RUPC P27284USPC P27715ESEP P28089DEEP P28089ESEP P28089ITEP P28089USPC P28090EP00 P31160ESES P31160PC...