Site Preparation
MC1600 Extreme Edge Server Installation and Use (6806870A02A)
75
2.6
Electromechanical
Dual (redundant) -48V power input connections
High-efficiency fans in N+1 configuration with temperature sensor-based tachometer
control
Mechanical dimensions: 1U (H) x 19” (W) x 12” (D)
(44.5mm x 482.6mm x 304.8mm)
2.7
Environmental
2.7.1
Environmental Conditions
To ensure proper function, do not operate equipment outside of the specified operating
environment.
Proper operation requires adherence to environmental conditions for deployed systems. This
includes adherence to environmental conditions when Artesyn or third-party system
components are integrated at an installation site. The Extreme Edge Server is designed to
operate under the following environmental conditions.
The Extreme Edge Server is designed for installation in an IP55/IP65 19" outdoor cabinet and is
compliant to an IP20 Ingress Protection Rating.
External air filtering may be needed if installed in a location other than an IP55/IP65 cabinet.
Table 2-3
Environmental Conditions
Characteristic
Condition
Operating temperature
0
C to 65
C without optional heater
-40
C to +65
C with heater* (at the air inlet)
Storage temperature
-40
C to +70
C
Humidity range
5% to 95% noncondensing
Operating Altitude
-60m to 1800m without temperature derating, up to 4000m with
temperature derating of 1C per 300m above 1800m
Operating Vibration
GR-3108-CORE Class 2 vibration
Summary of Contents for MaxCore MC1600
Page 1: ...MaxCore MC1600 Extreme Edge Server Installation and Use 6806870A02A April 2019...
Page 8: ...List of Figures 6 MC1600 Extreme Edge Server Installation and Use 6806870A02A...
Page 26: ...Safety Notes 24 MaxCore MC1600 Extreme Edge Server Safety Notes Summary 6806870A04A...
Page 36: ...Sicherheitshinweise 34 MaxCore MC1600 Extreme Edge Server Safety Notes Summary 6806870A04A...
Page 116: ...Related Documentation 114 MC1600 Extreme Edge Server Installation and Use 6806870A02A...
Page 117: ......