System Overview
MC1600 Extreme Edge Server Installation and Use (6806870A02A)
65
Private I
2
C Buses
—
6x temperature sensors
—
2x voltage sensors
—
Real time clock
Additional GPIO
—
Fan control: 3x PWM out, 7x tachometer in with noise filter
—
Analog voltage sensing for critical voltages
BMC Debug Options
—
8x debug LED (green), 1x heartbeat LED (red)
—
4x debug switch (DIP switch type)
—
Console output via 3-pin header, R-232
PCIe
—
PCIe GEN1 x1 link (endpoint) to CPU1 (root)
1.12.3 BMC Private I
2
C Buses
The two private I
2
C buses of the BMC, which are directly connected to the BMC, include
discrete temperature sensors, voltage sensors, an RTC, and an optional FRU EEPROM. There are
also routing resistors on the board that allow connection of these buses to the Glue CPLD as a
BOM option. The I
2
C addresses of the devices are shown in the following tables.
Table 1-17 BMC I
2
C Bus 8 Devices
7-bit Addr
8-bit Addr
Description
0x49
0x92
Temperature sensor
0x4A
0x94
Temperature sensor
0x4B
0x96
Temperature sensor
0x4C
0x98
Temperature sensor
0x50
0xA0
Optional FRU EEPROM (BOM option)
Summary of Contents for MaxCore MC1600
Page 1: ...MaxCore MC1600 Extreme Edge Server Installation and Use 6806870A02A April 2019...
Page 8: ...List of Figures 6 MC1600 Extreme Edge Server Installation and Use 6806870A02A...
Page 26: ...Safety Notes 24 MaxCore MC1600 Extreme Edge Server Safety Notes Summary 6806870A04A...
Page 36: ...Sicherheitshinweise 34 MaxCore MC1600 Extreme Edge Server Safety Notes Summary 6806870A04A...
Page 116: ...Related Documentation 114 MC1600 Extreme Edge Server Installation and Use 6806870A02A...
Page 117: ......