Functional Description
SharpStreamer™ PCIE-7207 Installation and Use (6806800T60F)
45
3.8
Reset Management
Each MCP reset is controlled by the CPLD. During power up the CPLD state machine drives the
reset control to each MCP. During an induced reset from the server, the GPIO on the i350
controller triggers a reset to the CPLD GPIO input, which in turn sends the reset to the selected
individual MCP processor complex through the CPLD GPIO. The i218 receives the reset from
the PCH platform reset. The following figure shows the internal reset architecture of the PCIE-
7207 card.
There is a physical push button that connects directly to the CPLD and is an external reset for
all the MCP complexes.The PCIe reset from the PCIe connector connects directly to the i350
reset. For more information about Reset button, refer the section
.
Figure 3-4
Reset Architecture
DRAM Devices
RESET_N
RESET_N
RESET_N
RESET_N
RESET_N
RESET_N
RESET_N
SM_DRAMRST#
RESET_N
Broadwell-U
CPLD
SYS_RESET_N
XDP
I218 PHY
PE_RST_N
PCIe Edge Conn
PERST#
I350 Ethernet
PE_RST_N
PCH_PWROK
SYS_PWROK
3.3V_ATX Reg
PG
APWROK
DPWROK
SLP_S3_N
PWRBTN_N
SRTCRST_N
RTCRST_N
3.3V_ATX
Boot Flash
RESET_N
3.3V_ATX
3.3V_ATX
PLTRST_N
RSMRST_N
RESET_IN
RESET_OUT
PWRGOOD
MicroSD Slot
RESET_N
GPIO8
0 ohm
CPU Complex (x4)
Summary of Contents for SharpStreamer PCIE-7207
Page 1: ...SharpStreamer PCIE 7207 Installation and Use P N 6806800T60F May 2016 ...
Page 8: ...SharpStreamer PCIE 7207 Installation and Use 6806800T60F 8 List of Tables ...
Page 10: ...SharpStreamer PCIE 7207 Installation and Use 6806800T60F 10 List of Figures ...
Page 20: ...SharpStreamer PCIE 7207 Installation and Use 6806800T60F Safety Notes 20 ...
Page 24: ...SharpStreamer PCIE 7207 Installation and Use 6806800T60F Sicherheitshinweise 24 ...
Page 30: ...Introduction SharpStreamer PCIE 7207 Installation and Use 6806800T60F 30 ...
Page 76: ...BIOS SharpStreamer PCIE 7207 Installation and Use 6806800T60F 76 ...
Page 108: ...SSF Installation SharpStreamer PCIE 7207 Installation and Use 6806800T60F 108 ...
Page 112: ...ViewCheck Installation SharpStreamer PCIE 7207 Installation and Use 6806800T60F 112 ...
Page 116: ...Related Documentation SharpStreamer PCIE 7207 Installation and Use 6806800T60F 116 ...
Page 117: ......