IPMI Feature Set
ATCA-7490 Installation and Use (6806800U11F)
351
When the Failsafe logic is triggered as a result of the BMC Watchdog timeout, a System
Firmware Progress event is logged as follows:
Sensor Type: 0x0F (System Firmware Progress)
Event Reading Type Code: 0x6F (Sensor Specific)
Event Data Byte 1: 0xA1 (System Firmware Hang)
Event Data Byte 2: 0x00 (CPU instance)
Event Data Byte 3: 0xXX (Failed Boot Bank ID: 0=Bank A; 1=Bank B)
The Failsafe logic makes three attempts to boot the payload successfully. After three attempts,
the Failsafe logic is automatically disabled and the boot bank is left in the original state (before
the payload was booted).
Payload software is able to detect when failsafe was activated during last boot. For details, see
By default, Failsafe is disabled.
9.13 Glue Logic FPGA Flash Selection
The ATCA-7490 provides redundant FPGA flashes for both manual and automatic crisis
recoveries.
The general concept is that there is always an active and a standby SPI flash device. The role of
these two devices can be reversed by the IPMC; for this to work, the IPMC has to drive the chip
select signals to the SPI flashes. The final decision about which of the two devices is active and
standby is made by the IPMC.
Due to the fact that the Glue Logic FPGA is powered by management power, the IPMC needs to
control the Glue Logic FPGA during power-up.
The FPGA Bank selection is implemented such that swapping the SPI flashes is in effect
immediately. Nevertheless due to the FPGA is already loaded during power-up, the SPI flash
selection does not enforce the FPGA to reload. Furthermore, in case of the payload, powered
(M4) FPGA cannot be loaded neither.
Therefore, swapping FPGA bank is possible only with the following steps:
1. Swap the FPGA banks
2. Power-cycle the payload
Summary of Contents for ATCA-7490
Page 1: ...ATCA 7490 Installation and Use P N 6806800U11F December 2018 ...
Page 12: ...ATCA 7490 Installation and Use 6806800U11F Contents 12 Contents Contents ...
Page 20: ...ATCA 7490 Installation and Use 6806800U11F 20 List of Tables ...
Page 38: ...ATCA 7490 Installation and Use 6806800U11F Sicherheitshinweise 38 ...
Page 44: ...Introduction ATCA 7490 Installation and Use 6806800U11F 44 ...
Page 66: ...Hardware Preparation and Installation ATCA 7490 Installation and Use 6806800U11F 66 ...
Page 88: ...Controls Indicators and Connectors ATCA 7490 Installation and Use 6806800U11F 88 ...
Page 106: ...Functional Description ATCA 7490 Installation and Use 6806800U11F 106 ...
Page 199: ...BIOS ATCA 7490 Installation and Use 6806800U11F 199 Add an ISCSI Attempt ...
Page 226: ...BIOS ATCA 7490 Installation and Use 6806800U11F 226 Figure 6 25 Event Log Viewer ...
Page 356: ...IPMI Feature Set ATCA 7490 Installation and Use 6806800U11F 356 ...
Page 360: ...Replacing the Battery ATCA 7490 Installation and Use 6806800U11F 360 ...
Page 371: ......