Base Operating System
SharpStreamer™ Pro PCIE-7210 Installation and Use ( 6806800U29D)
107
Host machine OS
: Same distribution as Base OS ISO.
For example, if Base OS is based on CentOS7.2, then use a host machine installed with
CentOS7.2.
Procedure
To modify ramfs, perform the following steps:
1. Mount the Base OS ISO to a directory.
For example, /mnt directory.
$ mount –t MC3K_7210_OS_CENTOS72_DIST_<Revision and Version
number>.iso /mnt
2. Unpack
ramfs.xz
to a location.
For example, to uncompress ramfs.gz to
/tmp/rootfs
directory.
$ sh /mnt/utils/unpackinitramfs /mnt/images/ramfs.xz
/tmp/rootfs
3. Modify the
/tmp/rootfs
according to your requirements.
4. Repackage
ramfs.xz
from
/tmp/rootfs
, using any of the below commands.
$ sh /mnt/utils/mkinitramfs /tmp/rootfs /tmp/ramfs.xz
(xz compression: less space, slower compression, slower booting).
or
$ sh /mnt/utils/mkinitramfs /tmp/rootfs /tmp/ramfs.gz
(gz compression: more space, faster compression, faster booting)
5. Modify the
files.sha1sum
file with updated
sha1sum
of
ramfs.xz
or
ramfs.gz
.
files1.sha1sum
is used during installation and it needs to be in the same location as
ramfs.gz
/
ramfs.xz
sha1sum ramfs.xz > files.sha1sum
or
sha1sum ramfs.gz > files.sha1sum
Summary of Contents for 6806800U29D
Page 1: ...SharpStreamer Pro PCIE 7210 Installation and Use P N 6806800U29D September 2017...
Page 8: ...SharpStreamer Pro PCIE 7210 Installation and Use 6806800U29D 8 Contents...
Page 10: ...SharpStreamer Pro PCIE 7210 Installation and Use 6806800U29D 10 List of Tables...
Page 12: ...SharpStreamer Pro PCIE 7210 Installation and Use 6806800U29D 12 List of Figures...
Page 20: ...SharpStreamer Pro PCIE 7210 Installation and Use 6806800U29D Safety Notes 20...
Page 24: ...SharpStreamer Pro PCIE 7210 Installation and Use 6806800U29D Sicherheitshinweise 24...
Page 30: ...Introduction SharpStreamer Pro PCIE 7210 Installation and Use 6806800U29D 30...
Page 48: ...Functional Description SharpStreamer Pro PCIE 7210 Installation and Use 6806800U29D 48...
Page 92: ...BIOS SharpStreamer Pro PCIE 7210 Installation and Use 6806800U29D 92...
Page 108: ...Base Operating System SharpStreamer Pro PCIE 7210 Installation and Use 6806800U29D 108...
Page 140: ...MaxCore Firmware Upgrade SharpStreamer Pro PCIE 7210 Installation and Use 6806800U29D 140...
Page 142: ...Related Documentation SharpStreamer Pro PCIE 7210 Installation and Use 6806800U29D 142...
Page 143: ......