User´s Manual 

 

 

Summary of Contents for saTECH RIO

Page 1: ...saTECH RIO User s Manual...

Page 2: ...te September 2014 Electrot cnica Arteche Smart Grid S L RESTRICTED USE DOCUMENT Reproduction of all or part of this information is prohibited without prior express written permission Document subject...

Page 3: ...hapter 5 Front 14 Chapter 6 Wiring 15 6 1 Grounding 15 6 2 Power supply terminal 16 6 3 Communications 16 6 3 1 Connections on the unit s front panel 16 6 3 2 Ethernet Ports 17 6 3 3 Serial Ports 18 6...

Page 4: ...ures Communications Three Ethernet 10 100 Mbps ports Front RJ45 output and two rear outputs with RJ45 or ST type fibre optic options prepared to provide physical redundancy Four configurable RS232 or...

Page 5: ...to isolated digital inputs for 125 Vdc bias voltage Isolated inputs with independent common or grouped in sets with a common each 8 inputs 2500 Vrms isolation voltage Plug in terminals with bracket In...

Page 6: ...4 4 2012 Class 4 4kV to 5kHz Immunity to shock waves IEC 61000 4 5 2006 Class 4 4kV in common 2kV in differential mode in 1 2 50us Immunity to conducted disturbances IEC 61000 4 6 2009 10 Vrms 0 15 t...

Page 7: ...of the command is recorded in the events page Event module with millisecond accuracy Possibility to download the event log via USB Alarm module with acknowledgment Watchdog Software Communications Com...

Page 8: ...abase module with native IEC 61850 memory Remote management Secure FTP Server SFTP SSH Server Configuration Tools Configuration and local maintenance tools via LCD display The equipment is configured...

Page 9: ...INTRODUCTION saTECH RIO User s Manual Rev 1 0 9 1 5 Mechanical Dimensions The saTECH RIO unit s main dimensions are shown in all specifications are in millimetres Figure 1 Dimension drawing...

Page 10: ...damage to saTECH RIO as well as injuries in the event of an accident Never connect or disconnect a cable and or connector to from a saTECH RIO during normal operation Existing dangerous currents and...

Page 11: ...ble damage suffered during transport If necessary contact the supplier 3 If the saTECH RIO is to be stored before installation it should be stored in the original packaging in a clean and dry place 3...

Page 12: ...User s Manual Rev 1 0 12 5 Check that it is connected Figure 3 Front view of saTECH RIO 6 Check that the LEDs are working by pressing TEST LED 7 Make sure the software is as requested If not please c...

Page 13: ...is ready for assembly in a 19 rack its height is 88 90 mm 2U Sufficient space must be left both at the front and at the back for connections maintenance tasks and for changing modules 4 1 Assembly Th...

Page 14: ...anual Rev 1 0 14 Chapter 5 Front The main elements present in the front of the unit are described below Figure 5 Description of front LCD DISPLAY KEYPAD LED MATRIX MAINTENANCE PORTS SERIAL PORT INDICA...

Page 15: ...et and tie screw connection Direct capture from current and power transformers via cables with tipped or ringed termination screwed to a plug in terminal Figure 6 Plug in terminals with side bracket a...

Page 16: ...3 Communications 6 3 1 Connections on the unit s front panel The front of the saTECH RIO is equipped with a connector with 2 USB ports and an Ethernet port with an RJ45 terminal and a mini USB port f...

Page 17: ...45 connectors can be used as the device has Auto MDIX Ethernet connection with fibre optic following a request for the ETH FO module ST Connector LC Connector A glass fibre optic cable with ST type co...

Page 18: ...RS232 or RS485 serial ports two or four wires Nine wire cable with DB 9 male connectors is to be used The following table shows the connector pins of the DB 9 female connectors available in saTECH BC...

Page 19: ...rent types of connection depending on the module chosen are described below It must be remembered that there are two types of module bus and expander but that this is not important when they are being...

Page 20: ...c application This enables the hardware resources to be adjusted to the application s software requirements 7 2 saTECH RIO saTECH RIO is a unit that interconnection between units for the transmission...

Page 21: ...on Event log module Goose 61850 message server module Goose 61850 message client module Digital output activation module Local LCD display management module NTP or IRIG B synchronization management mo...

Page 22: ...O The following first level menu structure is shown Figure 15 Directory tree Each of the above options will enable the configuration or display of the different options to be displayed configured 8 1...

Page 23: ...ay of the unit s general parameters as well as the unit s configuration information beyond the remote control communication protocols time date passwords display etc The screen structure is as shown i...

Page 24: ...anual Rev 1 0 24 8 1 3 Configuration of communications Enables the configuration of the unit s serial and Ethernet communications The menu allows the parameters marked in green in the following screen...

Page 25: ...ing the different versions of the unit and of its components The menu is shown in the following menu Figure 20 Diagnostic menu 8 1 5 Save Changes Menu configuration Enables the changes effected in the...

Page 26: ...s with independent common 19 Figure 9 32 opto isolated digital input modules with independent common each 8 inputs 19 Figure 10 16 electromechanical relay digital output modules 19 Figure 11 16 opto i...

Page 27: ...www arteche com Arteche...