Page 2: ...duction 3 Installation and Use 4 Configuring the Temperature Controller 10 Working with Thermistors 10 TEC Lifetime 12 Connector Pin Outs 13 Technical Specifications 14 Thermal Capacity 15 Mechanical...

Page 3: ...a larger 1 threaded opening compatible with 1 lens tube systems When coupled with the 234 OFFSET KIT the 234B can be used with 2 pin 1mm offset mounted lasers from manufacturers such as the Nichia Mi...

Page 4: ...ave the photodiode cathode except for style G lasers in which case the left hole is laser cathode and the right hole would have the laser anode When installing your laser the isolated non common photo...

Page 5: ...PD LD LD LDA PDA N C PD LD PDC LDC PD LD LD COM PD LD LD LDA PDA N C PD LD PDC LDC PD LD LD COM PD LD LD Anode and PD Cathode Common Style A or E Common Cathode Style B or H LD Cathode PD Anode Commo...

Page 6: ...esigned to connect directly between our LaserSource and TECSource products If you use your own cables ensure the connections are properly made between the instrument and the mount and that proper grou...

Page 7: ...iled device would mount in a similar fashion Your pin length must be in the range of 5mm to 9mm most diodes are 6 25mm Longer pins must be trimmed or they will bend when clamping the diode No Laser La...

Page 8: ...r as poor or uneven temperature control may result the two pictures below show a correct and improper use of the diode clip GOOD Diode properly clamped BAD Diode improperly clamped clip is even with c...

Page 9: ...but will improve the temperature stability of the mount Depending on the type of the device choose the appropriate clip to mount it TO 5 6 and TO 9 clips TO 9 1mm offset clip 234B with diode loaded 2...

Page 10: ...ay be an upgrade available for your instrument check with the factory for more information or simply adjust the current limit to no more than the maximum current of the 234B If you will be using a non...

Page 11: ...minimize noise and maximize stability you should select highest current while still allowing you full operation across your required temperature range The typical setting is 100 A but your application...

Page 12: ...n compression or sheer or uneven loads Arroyo Instruments mounts are designed to avoid these conditions but can still be induced by customer loads in the final application The first two issues can be...

Page 13: ...todiode anode 8 9 Laser anode Laser DB 9 Connector Pin Out DB 15 Pin Description 1 2 TE 3 4 TE 7 Thermistor 8 Thermistor 11 FAN 12 FAN 5 6 9 15 No connection TEC DB 15 Connector Pin Out The nitrogen f...

Page 14: ...o 85 C Sensor Type 10k Thermistor TE Module at 25 C Imax 5 6A Vmax 7 2V Recommended Controller 5305 or 5240 TECSource Mechanical Summary Maximum Thread Depth in mm 0 15 3 8mm Center hole 0 27 6 9mm st...

Page 15: ...0 5 0 10 0 15 0 20 0 25 0 10 0 10 20 30 40 50 60 70 Maximum Thermal Load W Plate Temperature C 234 Thermal Capacity 25 C Ambient When operating at temperatures that cause condensation below the dew po...

Page 16: ...Page 16 234B Series TEC TO Can LaserMount User s Manual v Mechanical Specifications Front Detail View...

Page 17: ...234B Series TEC TO Can LaserMount User s Manual Page 17 TO 5 6 Clip TO 9 Clip...

Page 18: ...Page 18 234B Series TEC TO Can LaserMount User s Manual TO 9 1mm Offset Clip 234B with Standard Cover Front View...

Page 19: ...234B Series TEC TO Can LaserMount User s Manual Page 19 234B with 1mm Offset Cover Front View 234B with Standard or 1mm Offset Covers Side View...

Page 20: ...Page 20 234B Series TEC TO Can LaserMount User s Manual 234B with 234 C 02 Cover Front View 234B with 234 C 02 Cover Side View...

Page 21: ...234B Series TEC TO Can LaserMount User s Manual Page 21 Bottom View Rear View...

Page 22: ...lso provides additional current limiting protection from ESD 2 Always work in an ESD safe operating environment including the use of wrist straps ESD grounded work surfaces and floors and ESD safe too...

Page 23: ...ormal conditions of operation If found to be defective during the warranty period the product will either be repaired or replaced at Arroyo Instruments s option THIS WARRANTY IS IN LIEU OF ALL OTHER W...

Page 24: ...Page 24 234B Series TEC TO Can LaserMount User s Manual Copyright 2022 Arroyo Instruments All Rights Reserved 530 1034 Rev D...