Physical Inst
allatio
n
19
Physical Installation
WARNING! Attach an approved safety-cable to
secure the product and accessories against clamp or
bracket failure when the product is mounted above
floor. The safety-cable needs to be approved at least
10 times the weight of the product including all acces-
sories mounted at the product. The safety cable must
comply with EN 60598-2-17 Section 17.6.6 and be
approved by an official body such as TÜV. Lead the
safety-cable through the stirrup and keep it as short
as possible. The handle and the floor stand must not
be used as an anchor for the safety-cable.
WARNING! The rigging structure needs to be
approved for at least 10 times the weight of all
devices, equipment and cables installed on it.
WARNING! The stirrup must be mounted hanging or
standing vertically. Lateral load can cause deforma-
tion or breaking of the spigot and the stirrup.
CAUTION! Block access below the work area and
work from a stable platform whenever installing, ser-
vicing or moving the product or accessories.
IMPORTANT! Do not illuminate the display and the
diffuser plate by high power light beams from a short
distance. The display and the light engine are dam-
aged by high brightness and heat radiation within
very short time.
To Mount the Stirrup And the Spigot
You need:
• a 10 mm allen key (manual version)
• a 8 mm allen key (p.o. version)
• a 4 mm allen key
• a torque wrench with 10 mm or 8 mm and 4 mm allen socket
To Mount the Spigot (manual version)
Place the spigot on the 13 mm hole in the middle of the stirrup.
Insert the allen screw with washer and spring washer and
tighten it with a torque wrench to 37 ft-lb. torque.
To Mount the Spigot (p.o. version)
Insert the allen screw with washer and spring washer in the
spigot. Place the spigot on the upper side of the gear in the
middle of the spigot. Tighten the allen screw with a torque
wrench to 22 ft-lb. torque.