background image

User Manual

April 2016

Summary of Contents for SkyPanel

Page 1: ...User Manual April 2016 ...

Page 2: ...gs Ltd L5 0006983 Rev L02798 2015 Arnold Richter Cine Technik GmbH Co Betriebs KG ARRI All rights reserved Information subject to change without notice ARRI and all affiliated companies disclaim liability for any injury damage direct or indirect loss consequential or economic loss or any other loss occasioned by the use of inability to use or reliance on the information contained in this document ...

Page 3: ...Dimensions 3 Dimensions SkyPanel S30 manual version ...

Page 4: ...Dimensions 4 SkyPanel S30 P O Version ...

Page 5: ...Dimensions 5 SkyPanel S60 manual version ...

Page 6: ...Dimensions 6 SkyPanel S60 P O Version ...

Page 7: ...s and Indications 9 General Notes 9 General Safety Information 10 Specific Safety Information 11 Replacing the Light Source 12 Firmware Downgrade 12 Maintenance Information 12 Intended use 12 Introduction 13 Features 13 Properties 14 Unpacking 14 Overview 15 Manual Version 15 P O Version 16 Power Supply Unit S60 18 Power Supply Unit S30 18 Physical Installation 19 To Mount the Stirrup And the Spig...

Page 8: ...f the Fixture Menu 27 Feature of the Fixture Menu 27 Fixture Control 35 Art Net 36 DMX 37 Tips for a Reliable Data Transmission 37 To Connect the Data Link 37 Fixture Menu 38 RDM commands 42 Required RDM command extensions 43 Manufacturer commands 44 Error Codes 46 ARRI Lighting Service Manager 47 Protocol 48 SkyPanel RP 48 SkyPanel C 49 Specification 66 ...

Page 9: ...s important instructions and notes to handle the product safe Always follow all safety information for your own protection Please contact a trained ARRI service technician to do any service and maintenance not described in this manual Please follow the user manual of accessories and third party accessories such as battery packs and battery chargers They contain important safety and security inform...

Page 10: ...repair work is only to be carried out by an authorized ARRI service center Do not operate the product if the ambient tempera ture exceeds 45 C Observe all information given in chapter Specification on page 66 Do not expose the product to rain or moisture Do not use the product for 2 h when it was exposed to big temperature differences as condensed moisture may damage the product electrically when ...

Page 11: ...ateral load can cause deformation or breaking of the spigot and the stirrup Devices and accessories must be secured against fall when mounted above floor level Always observe common and local safety regulations Never use the cables for transportation Never hang the product on its cables Do not hang a battery pack on its connection cable to the product Always check that the local AC power matches t...

Page 12: ...firmware to a version lower 1 0 0 after updating to version 1 0 0 or higher Maintenance Information Do not clean the surface of the product with solvents or strong detergents Clean the product with a soft cloth wetted with a mild deter gent Do not rub the surface lift stuck particles off with a soft repeated press Clean soiled electric contacts with cotton swabs wetted with isopropyle alcohol Keep...

Page 13: ... digital cameras All models of the SkyPanel can be controlled using the common DMX512 A protocol the Art Net protocol or the fixture menu The SkyPanel is powered by AC power or a battery pack Please find more detailed information in section To Power the SkyPanel on page 24 Features Light Field The SkyPanel offers the same functionality as a conventional softlight Even Light Field The SkyPanel soft...

Page 14: ... are controllable through DMX or Art Net The SkyPanel is also fully RDM compatible both via DMX and Art Net with suitable controllers and is equipped with a feedback channel for reporting all set parameters including system status Fixture Menu For location applications the SkyPanel is equipped with a fixture menu for manual adjustment of intensity color temper ature and plus minus green as well as...

Page 15: ...verview Manual Version Diffusor or remote phosphor panel Top latches Stirrup Handle Tilt lock Tilt lock lever Fixture menu Connector panel Spigot Figure 1 Front and back view manual version the figure shows the S60 ...

Page 16: ...Overview 16 P O Version Diffusor or remote phosphor panel Top latches Stirrup Handle P O drives Fixture menu Connector panel Spigot Figure 2 Front and back view P O version the figure shows the S30 ...

Page 17: ...Overview 17 USB A Ethernet DMX DMX connector Thru In port Power in 48 V Battery in 23 36 V Boot mode Figure 3 Connector panel ...

Page 18: ...wer Supply Unit S60 Power Supply Unit S30 Power in and thru Power out 48 V Main switch Figure 4 Power supply unit S60 Power out 48 V Main switch Front panel Power in and thru Back panel Figure 5 Power supply unit S30 ...

Page 19: ... tion or breaking of the spigot and the stirrup CAUTION Block access below the work area and work from a stable platform whenever installing ser vicing or moving the product or accessories IMPORTANT Do not illuminate the display and the diffuser plate by high power light beams from a short distance The display and the light engine are dam aged by high brightness and heat radiation within very shor...

Page 20: ...onjunction the Center mount yoke L2 0008078 and Fixed center mount yoke L2 0008080 The brackets are in tended to be used as an anchor point for a safety cable To Dismantle the Stirrup Place the SkyPanel with the lighting aperture facing down wards on an even and clean surface Loosen and remove two allen screws on each side of the product 4 mm allen key see Figure 6 Remove the stirrup To Mount the ...

Page 21: ...nd accessories Keep care that Both guiding rails are locked Tripods are set up in a stable position Tripods need to be ap proved for the load they need to carry Always observe the additional load of cables and accessories Top latch locked Top latch unlocked Figure 8 Locking top latches Figure 7 To mount the safety loop brackets ...

Page 22: ...ver strip see Figure 8 Insert the accessory from the top completely into the guiding rails Close the cover strip Lock both top latches by sliding both levers completely outwards see Figure 8 To Mount a Barndoor A barndoor is mounted using the outer guiding rails see Figure 9 Close the cover strip Lock both top latches by sliding both le vers completely outwards see Figure 8 Insert the barndoor com...

Page 23: ...ervice purpose like downloading error re ports from the product and set certain data To do so you need a software tool the ARRI Lighting Service Manager ALSM and an RJ45 network cable to connect your PC with the SkyPanel Download the ALSM free of charge from the ARRI web site www arri com lightingsoftware Please find more detailed information to work with the ALSM in the user manual of the softwar...

Page 24: ...by an external power supply unit PSU The PSU is an auto sensing switch mode power supply that automatically adapts to AC power at 110 240 V 50 60 Hz nom Make sure that no person stares at the light output aperture and the product is isolated from DMX before you connect it to a power supply unit or a battery pack You can hard wire the SkyPanel to a building electrical instal lation You can install ...

Page 25: ...he raised key of the male cable connector and the keyway of the power out socket of the power supply unit In sert the cable connector without force in the power out socket until it locks To remove the cable connectors Press the connector lock and pull the cable connector out of the socket Power Through The external power supply is equipped with a Neutrik PowerCON True1 power output socket to suppl...

Page 26: ...s 45 V To Insert and Remove the 4 pin XLR Cable Connector To insert the 4 pin XLR cable connector The main switch of the battery pack must be turned off if possible Align the raised key of the cable connector with the keyway of the input socket see Figure 3 on page 17 Insert the cable connector without force in the input socket The cable connector must lock Repair or replace cable con nectors that...

Page 27: ...cation Blue The fixture receives a valid control signal Red No communication between fixture menu and main processor No light The fixture receives no valid control signal Color Indication Green No error Normal temperature Red flashing 0 5s rhythm Warning fixture over tempera ture only with fan modes LOW and High Speed Red Fixture over temperature Change from red to green Fixture normal temperature...

Page 28: ...lot Press I S 4 to store the preset Close the dialog with BACK MODE 8 MODE swaps between CCT HSI and GEL mode only Sky Panel C Press the MODE long to open Light Mode DISPLAY 9 The display shows the current settings and other information during normal operation Press the MENU button 4 to open or close the fixture menu Use I S 4 and the BACK button 11 to navigate through the fixture menu MENU 10 The...

Page 29: ...he intensity with I S 4 Press I S 4 again to re open the gel set To set the Brightness in all Operating Modes Set the brightness in both operating modes continuously with the encoder I S 4 The setting is dynamic Turning the enco der fast changes the intensity in coarse steps turning it slow changes the intensity in fine steps To set the dimming curve The SkyPanel supports four dimming curves The d...

Page 30: ...he light is dimmed and when the intensity drops to zero quickly there is a short afterglow of warm light This mode is perfect for mixing the SkyPanel with tungsten sources or for producing a familiar effect To set a special dimmer mode Press the MENU button 10 to open the fixture menu Turn I S until Light Control is selected Press I S to open the menu Turn I S until Special Modes is selected Press...

Page 31: ...Press I S to open the menu Select the Fan mode by turning I S Press I S to confirm the setting The menu Fan Mode closes automatically Press the MENU button to force closing the menu Option Description Hold Last Command The last received DMX values are used until the fixture is switched off or valid DMX data is received again Blackout The fixtures douses to 0 intensity immediately Hold for 2 min th...

Page 32: ...until Display Brightness is displayed Press I S to open the menu Select the desired brightness by turning I S Press I S to confirm the setting Turn I S until Display Contrast is displayed Press I S to open the menu Select the desired contrast by turning I S Press I S to confirm the setting Turn I S until Display Rotation is displayed Press I S to open the menu Select the desired setting by turning...

Page 33: ...ten by the selected preset list To save and load Fixture Settings The fixtures settings can be saved to an USB memory stick and uploaded to another SkyPanel The file contains all fixture set tings except the DMX address and IP settings To save the fixture settings Connect an USB memory stick to the USB A connector of the SkyPanel Press the MENU button 10 to open the fixture menu Turn I S until USB...

Page 34: ...to the USB A connector of the SkyPanel Press the MENU button 10 to open the fixture menu Turn I S until USB Functions is selected Press I S to open the menu Turn I S until Save Error Log is selected Press I S to open the menu Select Yes and press I S to confirm saving the log files Select No to abort saving the log files The log files will be saved on the USB memory stick To read out Fixture Infor...

Page 35: ...only mode It is used when the number of avail able channels of the controller is very limited It provides control of intensity color temperature and green CCT HSI only SkyPanel C Provides control of intensity color temperature green hue and saturation HSI hue saturation intensity In HSI mode the color and intensity is very even over the fixtures as it is con trolled using color algorithms which ta...

Page 36: ... Nets or 256 consecutive Uni verses is referred to as a net There are 128 Nets in total Sub Net A group of 16 consecutive universes is referred to as a sub net Not to be confused with the subnet mask Universe A single DMX512 frame of 512 channels is referred to as a Universe Art Net Merge Mode The Art Net protocol allows multiple nodes or controllers to transmit ArtDmx data to the same universe Me...

Page 37: ...Panels individual you need to set up additional DMX data links Tips for a Reliable Data Transmission Use shielded twisted pair cable designed for RS 485 devices or CAT 6 network cables Standard microphone cable cannot transmit control data reliably over long runs 24 AWG cable is suitable for runs up to 300 meters 1000 ft Heavier gauge cable and or an amplifier is recommended for longer runs To spl...

Page 38: ... Behavior Hold Last Command Fixture holds the last received control values Black Out Fixture douses the dimmer Hold 2 Min Fade Out Hold the last received values for 2 min then douse DMX Protocol Version Version x y Version of the DMX protocol Fan Mode Low Fan Speed Low fan speed silent operation Vari Fan Speed Temperature regulated fan speed High Fan Speed High fan speed best cooling Light Mode CC...

Page 39: ... alone effect Party Effect Stand alone effect see page 32 Display Setup Display Illumination Always On Display illumination always on Off After 10 Sec Display illumination douses 10 sec after last menu action Display Brightness 0 10 Brightness of the display illumination Display Contrast 01 03 10 Contrast of the display content Display Rotation Normal No rotation of the display content Upside Down...

Page 40: ...y Selector see page 33 Save Error Log No Store error and service log to an USB memory stick see page 34 Yes Art Net Settings Art Net Net 0 127 Select Art Net net see page 36 Art Net Subnet 0 15 Select Art Net subnet in Art Net net Art Net Universe 0 15 Select Art Net universe in Art Net subnet Art Net Merge Mode LTP Select Merge Mode LTP Last Take Precedence HTP Select Merge Mode HTP Highest Take ...

Page 41: ... Set network address manual see page 36 IP Address A B C D The fixtures IP address MAC Address u v w x y z The fixtures MAC address Network Name Sxx xxxxxxx xxx The fixtures network name ident and serial number Fixture Serial No L1 xxxxxxx xxx The fixtures serial number Firmware Version x xx xx xxxx The fixtures firmware version Display Version x xx xx xxxx The displays firmware version USB Mode N...

Page 42: ... not standard rdm commands mostly commands from manufacturer Describes the data type and shows if Set or Get or both are sup ported for the listed commands X Device Info Lists RDM protocol version device model ID product category software version ID from Main DMX footprint DMX personality sub device count and sender count X Software Version Label Shows the software version string from main e g Mai...

Page 43: ... Manufacturer Label Display the company name ARRI Lighting X Boot Software Version ID PrBo SW Version e g 2 03 00 X Boot Software Version Label Shows text from PrBo Bootloader e g PrBo 2 03 00 Jan 16 2012 19 10 26 X DMX Personality DMX mode X X DMX Personality Description Displays a text description of a DMX mode with up to 32 characters shown exactly as in the description in the ALSM X Slot Info ...

Page 44: ..._FULL_OFF 0x00 POWER_STATE_SHUTDOWN 0x01 X X Perform Selftest Supported test modes and demo modes X X Self Test Description Shows a description for each test demo mode X Command Description GET SET RDM Fan Mode PID 0x8001 Changes the FAN mode of the fixture this message supports Set and Get commands the first data byte is used to show change the fan mode USER_FAN_MODE_LOW 1 USER_FAN_MODE_VARI 2 US...

Page 45: ...If the DMX signal gets lost or the DMX device is unplugged the LED fixture holds the last valid signal or it holds the last valid signal for two minutes and then douses or switches off immediately Supported values 0 hold 1 hold 2 minutes 3 switch off X X Command Description GET SET ...

Page 46: ...un at all Set the fan to LOW or High Speed and see if it starts rotating in order to determine if there is an electrical malfunction All mechanical tests or repairs may only be carried out by a trained service technician E 011 Fixture menu module not be detected If the fixture menu is working error E 011 can be ignored However if the fixture menu remains dark no LED lights up we recommend to conta...

Page 47: ...8 PWM driver not found Switch the SkyPanel off and on again If the problem persists please contact the ARRI service E 019 Diffuser removed The diffusor was removed The protection circuit is active only RP version E 020 Update with errors This will be seen if the update process has detected an error during the update Please look at the error log for more information to see which model or component ...

Page 48: ... Function 1 0 255 0 100 Dimmer closed open 2 Reverts to fixture set ting when signal lost 0 9 10 60 61 120 121 180 181 250 251 255 0 4 5 23 24 47 48 70 71 98 99 100 Fan Control No function Low Variable High Fan max speed Fan off 3 5 Reserved only V4 x Channel Value Percent Function 1 HI 0 65 535 0 100 Dimmer closed open 2 LO 3 Reverts to fixture set ting when signal lost 0 9 10 60 61 120 121 180 1...

Page 49: ...de 14 RGBW Mode 5 HSI Mode 10 HSI Mode 15 HSI Mode 16 GEL Channel Value Percent Function 1 0 255 0 100 Dimmer closed open 2 0 255 0 100 Color temperature CCT 2 800 K 10 000 K 3 0 10 11 20 21 119 120 145 146 244 245 255 0 4 5 8 8 46 47 57 57 96 96 100 GN saturation neutral no effect full minus green 99 1 neutral no effect 1 99 full plus green 4 0 255 0 100 Xfade to color White RGBW color 5 0 255 0 ...

Page 50: ...100 Fan Control No function Low Variable High Fan max speed Fan off 5 7 Reserved only V4 x Channel Value Percent Function Channel Value Percent Function 1 0 255 0 100 Dimmer closed open 2 0 255 0 100 Color temperature CCT 2 800 K 10 000 K 3 0 10 11 20 21 119 120 145 146 244 245 255 0 4 5 8 8 46 47 57 57 96 96 100 GN saturation neutral no effect full minus green 99 1 neutral no effect 1 99 full plu...

Page 51: ...t ting when signal lost 0 9 10 60 61 120 121 180 181 250 251 255 0 4 5 23 24 47 48 70 71 98 99 100 Fan Control No function Low Variable High Fan max speed Fan off 7 9 Reserved only V4 x Channel Value Percent Function 1 0 255 0 100 Dimmer closed open 2 0 255 0 100 Hue 0 360 3 0 255 0 100 Saturation 0 full saturated 4 Reverts to fixture set ting when signal lost 0 9 10 60 61 120 121 180 181 250 251 ...

Page 52: ...hite 0 100 14 LO 15 Reverts to fixture set ting when signal lost 0 9 10 60 61 120 121 180 181 250 251 255 0 4 5 23 24 47 48 70 71 98 99 100 Fan Control No function Low Variable High Fan max speed Fan off 16 19 Reserved only V4 x Channel Value Percent Function 1 HI 0 65 535 0 100 Dimmer closed open 2 LO 3 HI 0 65 535 0 100 Color temperature CCT 2 800 K 10 000 K 4 LO 5 HI 0 5 000 5 001 10 000 10 001...

Page 53: ...0 LO 11 HI 0 65 535 0 100 Saturation 0 full saturated 12 LO 13 Reverts to fixture set ting when signal lost 0 9 10 60 61 120 121 180 181 250 251 255 0 4 5 23 24 47 48 70 71 98 99 100 Fan Control No function Low Variable High Fan max speed Fan off 14 16 Reserved only V4 x Channel Value Percent Function 1 HI 0 65 535 0 100 Dimmer closed open 2 LO 3 HI 0 65 535 0 100 Intensity red 0 100 4 LO 5 HI 0 6...

Page 54: ...e CCT coarse 2 800 K 10 000 K 4 0 255 0 100 Color temperature CCT fine 5 0 10 11 20 21 119 120 145 146 244 245 255 0 4 5 8 8 46 47 57 57 96 96 100 GN saturation neutral no effect full minus green 99 1 neutral no effect 1 99 full plus green 6 0 255 0 100 Xfade to color white RGBW color 7 0 255 0 100 Intensity red coarse 0 100 8 0 255 0 100 Red fine 9 0 255 0 100 Intensity green coarse 0 100 10 0 25...

Page 55: ... 7 9 Reserved only V4 x Channel Value Percent Function 1 0 255 0 100 Dimmer coarse closed open 2 0 255 0 100 Dimmer fine Channel Value Percent Function 3 0 255 0 100 Color temperature CCT coarse 2 800 K 10 000 K 4 0 255 0 100 Color temperature fine 5 0 10 11 20 21 119 120 145 146 244 245 255 0 4 5 8 8 46 47 57 57 96 96 100 GN saturation neutral no effect full minus green 99 1 neutral no effect 1 9...

Page 56: ... 11 Reverts to fixture set ting when signal lost 0 9 10 60 61 120 121 180 181 250 251 255 0 4 5 23 24 47 48 70 71 98 99 100 Fan Control No function Low Variable High Fan max speed Fan off 12 14 Reserved only V4 x Channel Value Percent Function 1 0 255 0 100 Dimmer coarse closed open 2 0 255 0 100 Dimmer fine 3 0 255 0 100 Hue coarse 0 360 4 0 255 0 100 Hue fine 5 0 255 0 100 Saturation coarse 0 fu...

Page 57: ...ansform CCT values in DMX values and vice versa CCT values SkyPanel C CCTmin 2 800 K CCTmax 10 000 K CCT value DMX value 8 bit DMX value 16 bit Sky panel C C 3 200 K 14 3 670 5 600 K 99 25 493 6 000 K 113 29 098 6 500 K 131 33 685 CCTTarget CCTmax CCTmin Channelin percent 100 CCTmin Channelin percent CCTrecent CCTmin CCTmax CCTmin 100 ...

Page 58: ...ilters 5 0 50 51 101 102 152 153 203 204 255 0 20 21 39 40 60 61 80 81 255 Gel category Manufacturer on ch 4 Category 1 Rosco Color Correction LEE Color Correction Category 2 Rosco CalColor LEE Color Filters Category 3 Rosco Storaro Selection LEE 600 Series Category 4 Rosco Cinelux LEE Cosmetic Filters No function Kanal Wert Prozent Funktion 6 0 255 0 100 Gel See tables below 7 Reverts to fixture ...

Page 59: ... 1 2 CTO 1 4 CTO 1 8 CTO Double CTO Full CTS 1 2 CTS 1 4 CTS 1 8 CTS Full Plusgreen 1 2 Plusgreen 1 4 Plusgreen 1 8 Plusgreen Full Minusgreen 3 4 Minusgreen 1 2 Minusgreen 1 4 Minusgreen 1 8 Minusgreen Fluorofilter 3202 3203 3204 3206 3208 3216 3220 3407 3411 3408 3409 3410 3420 3441 3442 3443 3444 3304 3315 3316 3317 3308 3309 3313 3314 3318 Chan Value Gel name Number 6 54 55 56 57 58 59 60 61 62...

Page 60: ...0 Red 90 Red 15 Magenta 30 Magenta 60 Magenta 90 Magenta 15 Pink 30 Pink 4215 4230 4260 4290 4307 4315 4330 4360 4390 4415 4430 4460 4490 4515 4530 4560 4590 4615 4630 4660 4690 4715 4730 4760 4790 4815 4830 Chan Value Gel name Number 54 55 56 57 58 59 60 61 62 63 64 65 66 255 60 Pink 90 Pink 15 Lavender 30 Lavender 60 Lavender 90 Lavender Reserved 4860 4890 4915 4930 4960 4990 Chan Value Gel name...

Page 61: ...e Pink Salmon Deep Salmon Middle Rose Light Rose Purple Surprise Pink No Color Blue Clearwater 2 302 6 8 310 12 16 316 17 18 318 21 321 23 325 26 33 333 34 37 41 42 44 47 51 60 360 Chan Value Gel name Number 6 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 255 Booster Blue Tipton Blue Blue Bell Daylight Blue Tharon Delft Blue Ce...

Page 62: ...ite Flame Green LEE Fluorescent Green Super Correction L C T Yellow Super Correction W F Green H M I to Tungsten C I D to Tungsten 200 201 281 202 203 218 287 204 285 205 206 223 283 286 441 442 443 444 207 208 212 213 219 230 232 236 237 Chan Value Gel name Number 6 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 255 C S I to Tungsten LEE Fluorescent 5700 Kelvin LEE Flu...

Page 63: ...e Evening Blue 002 003 004 007 008 009 010 013 017 019 020 021 022 024 025 026 035 036 046 048 052 053 058 061 063 068 075 Chan Value Gel name Number 6 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 Just Blue Deeper Blue Lime Green Moss Green Dark Yellow Green Spring Yellow Ye...

Page 64: ... No Color Straw Slate Blue Bastard Amber Flame Red Daylight Blue Lilac Tint Deep Lavender Dark Steel Blue Loving Amber Dark Lavender Light Red 134 135 136 137 138 140 142 143 144 147 148 151 152 153 154 156 157 159 161 162 164 165 169 170 174 176 180 182 Chan Value Gel name Number 6 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 255 Flesh Pink Surprise Pink Zenith Blue True Blue Alice...

Page 65: ...osmetic Peach Cosmetic Silver Rose Cosmetic Rouge Cosmetic Highlight Cosmetic Silver Moss Cosmetic Aqua Blue Lily Frost Shanklin Frost Half Shanklin Frost Durham Daylight Frost Hampshire Rose Durham Frost Soft Amber Key 1 Soft Amber Key 2 Moroccan Frost Blue Diffusion Blue Frost Daylight Blue frost Reserved 184 186 187 188 189 191 705 717 718 720 749 750 774 775 791 217 221 224 ...

Page 66: ...tirrup Weight w o accessories 13 kg 28 7 lbs Physical external power supply unit S30 Depth 383 mm 15 in Wide 90 mm 3 5 in Height 116 mm 4 6 in Weight 2 2 kg 4 8 lbs Physical external power supply unit S60 Depth 380 mm 15 in Wide 190 mm 7 5 in Height 90 mm 3 5 in Weight 3 7 kg 8 2 lbs Light source Type ARRI LED Light Engine Typ LED lifetime L70 50 000 h White light 2 800 K 10 000 K SkyPanel C White...

Page 67: ... 50 60 Hz nom Power output 48 V Power supply Auto sensing switching mode power supply Typical power 230 V 50 Hz 210 W nom SkyPanel S30 420 W nom SkyPanel S60 cos ϕ 0 9 Measurements made at nominal voltage with all LEDs at full intensity Allow for a deviation of 10 Noise emission Ambient temperature 35 C 95 F 20dB A Ambient temperature 45 C 113 F 30dB A Thermal Minimum ambient temperature ta 20 C 4...

Page 68: ...ck bare end L0 0007716 Accessories Standard Diffusion S30 L2 0007325 Heavy Diffusion S30 L2 0007326 Lite Diffusion S30 L2 0007327 Intensifier S30 L2 0007328 ARRI SkyPanel S30 RP White Light Interchangeable Remote Phosphor Panels S30 RP MAN blue silver 3 200 K Edison L0 0007717 S30 RP MAN blue silver 3 200 K Schuko L0 0007718 S30 RP MAN blue silver 3 200 K Chinese L0 0007720 S30 RP P O blue silver ...

Page 69: ...nior pin and p o drives DC header cable 48 V XLR 3 pin l 1 m 3 3 ft PowerCON TRUE1 mains cable l 3 m 10ft with bare ends ARRI SkyPanel S60 C Color Controllable Tuneable White 2 800 K 10 000 K Green Magenta Adjustment and Full RGBW Color Gamut S60 C MAN blue silver Edison L0 0007063 S60 C MAN blue silver Schuko L0 0007064 S60 C MAN blue silver Chinese L0 0007065 S60 C P O blue silver bare end L0 00...

Page 70: ...S60 blue silver L2 0007573 Power supply unit S60 black L2 0007878 Double vertical yoke S60 L2 0008098 Space Light silk mounting adapter S60 L2 0008185 Safety cable 5 mm l 1 m with Carabiner L2 80864 0 Accessories for all models S30 C S30 RP S60 C S60 RP Mains cable powerCON TRUE1 l 3 m Schuko L2 0007516 Mains cable powerCON TRUE1 l 3 m Edison L2 0007515 Mains cable powerCON TRUE1 l 3 m China L2 00...

Page 71: ...al radiation emitted from this product Specification subject to change without notice For the latest product specification including photometric data see www arri com In case of technical problems please visit us at www arri com to find the next ARRI service center www arri com ...

Page 72: ......