Salzburg TCBM-TCPW
05060203 00 03-2020
7
Schema elettrico 937 TCBM / Eelectric panel 937 TCBM
H O
2
1
2
Q.E.
ST
R3
R2
R1
H O
2
Q.E.
ST
R3
R2
R1
2
1
3
3
LEGENDA
SEZIONA
TORE GENERALE 4P 16A
MAIN SWITCH / HAUPTSCHAL
TER 4P 16A
QS
CONT
ATT
.RESISTENZE V
ASCA R1-R2-R3
W
ANNE HEIZUNG CONT
ATOREN R1-R2-R3
K1
A1
TERMOST
ATO TEMP
.V
ASCA 0/90°C
SPIA PRESENZA RETE VERDE
HL1
INTERRUT
.CARICO-SCARICO ACQUA
SA1
ST
TERMOST
ATO SIC.PK1-1CLL 145-131°C
SAFETY THERMOST
.PK1-1CLL 145-131°C
R1-2-3
RESISTENZA V
ASCA 900/1200W
BASIN HEA
TERS / W
ANNE HEIZUNG 900/1200W
LAMP
ADA RISCALDANTE 300W 230V
I1-2
FUSIBILI 6,3 x 32 GF
FUSES / SICHERUNG 6,3 x 32 GF
F....
CONT
ATT
.ILLUMIN.PLAF
.I1-I2-I3
BELEUCHTUNG DECKENLAMPE CONT
ATOREN I1-I2-I3
K2
INTERRUT
.VENTILA
TORI ANTI-CONDENSA
SA2
SPIA TERMOST
ATO ARANCIO
THERMOST
AT DIAL LAMP ORANGE / W
ANNENHEIZUNG BETRIEB
HL2
INTERRUTTORE ILLUMINAZIONE
SA3
HL3
SPIA ALLARME LIVELLO MINIMO ACQUA
W
ATER MIN.LEVEL ALARM LAMP / W
ASSERST
AND ZU NIEDRIG
03
04
02
01
U
V
PE
W
N
K1
R1
R2
R3
N
N
N
K1
0.5A
FS
A1
A1
A2
B2
B3
230V
COMUNE
LIV. MIN
CONTROLLORE LIVELLO FINDER 72.01.8.240
50/60HZ
B1
LIV. MAX
14
11
12
N
5
SA1
10A
FR3
10A
FR2
10A
FR1
07
06
05
18
15
QS
HL1
HL3
FA 0.5A
F5 5A
14
17
13
19
16
HL2
1A
F2
08
SA2
2
N
11
SA3
12
K2
5A
FI1
5A
FI2
K2
10
09
I1
I2
NI
C
1
3P+N 400V 50/60HZ
SPEISUNG
ALIMENT
AZIONE
RESISTENZA
HEIZUNG
RESISTENZA
HEIZUNG
RESISTENZA
HEIZUNG
+131°C
+145°C
+131°C
+145°C
+131°C
+145°C
R3
R2
R1
ST
ST
ST
VENTILATORI ANTI-CONDENSA
LUEFTER
1
M
CANOPY CONNECTION WIRE
CA
VO DI COLLEGAMENTO ALLA PLAFONIERA
3
1
2
2
1
3
PLAFONIERA RISCALDANTE
HEIZUNG DECKENLAMPE
3
I1
I2
GREEN SUPPL
Y DIAL LAMP / BETRIEBSBEREIT
HALOGEN LAMP / HEIZUNG LAMPE 300W 230V
SCHEIBEN HINTERLUEFTUNG
W
ATER CHARGE-DISCHARGE SWITCH / W
ASSER EINLASS - W
ASSER STOP
LIGHT SWITCH / LICHTSCHAL
TER
BASIN TEMPERA
T.THERMOST
AT / W
ANNENTHERMOST
AT 0/90°C