The performance of these refrigerated counters was determined through tests conducted in
compliance with the standard
EN ISO 23953-2: 2016
in the environmental conditions that
correspond to climatic class 3 (25°C, 60% R.H.) see table:
The weight of water vapour in dry air is one of the main points that affect the performance and
power consumption of the counters.
The safety test is carried out in accordance with standards IEC EN 60335-2-89 at an ambient
temperature of 32°C +/-2°C.
6. Identification - Rating Plate
The serial plate with all the technical specifications (Fig. 2) is affixed to the side of the cabinet:
EMC
Electromagnetic compatibility
2014/30/EU
EN 61000-3-2: 2019;
EN 61000-3-3: 2020;
EN 61000-3-11: 2020;
EN 55014-1: 2019;
EN 55014-2: 2016
Electromagnetic
Compatibility Regulation
2016.
RoHS
RoHs Directive 2011/65/EC
(restricted use of certain
hazardous substances in electrical
and electronic equipment)
EN 50581: 2012
Regulations 2012
(restricted use of certain
hazardous substances in
electrical and electronic
equipment).
Ecodesign and
Energy label-
ling
Directive 2009/125/EC
Regulation implementing EU
2019/2024
(ecodesign specification for
refrigeration appliances with
direct sales function)
EN ISO 23953-2: 2016
Ecodesign for energy-
related products and
energy information.
2010 Standards as
reflected in UK law and
subsequent
modifications.
Compliance with the requirements and standards are present in the generic facsimile of
the Declaration of Conformity at the end of this manual.
These models are excluded from the scope of the Directive 2014/68/EU in accordance
with article 4 paragraph 3 (and/or article 1 paragraph 2 letter f).
Climatic Class of the
testing chamber
Temperature
dry bulb
Relative
Humidity
Dew
point
Weight of water
vapour in dry air
°C
%
°C
g/kg
0
20
50
9,3
7,3
1
16
80
12,6
9,1
2
22
65
15,2
10,8
3
25
60
16,7
12,0
4
30
55
20,0
14,8
6
27
70
21,1
15,8
5
40
40
23,9
18,8
7
35
75
30,0
27,3
8
23,9
55
14,3
10,2
Declaration of
conformity
A copy of the conformity statement is annexed to the counter.
If the original copy of the Declaration of Conformity supplied with the unit is
lost, download a copy by filling out the form found in the footer of the home
page of the website www.arneg.it under "EU compliance".
N°
Trade
1
name and address of the manufacturer
2
name and length of the cabinet
3
code of the cabinet
4
serial number of the cabinet
5
supply voltage
6
power supply frequency
7
operating current consumption
8
operating electrical power absorbed in the refrigeration phase (fans+hot wires+lighting)