53
Recommended separation distances between portable and mobile RF communications equipment and the
Maxi Twin
lift.
The
Maxi Twin
lift is intended for use in an electromagnetic environment in which radiated RF disturbances are
controlled.
The customer or the user of the
Maxi Twin
lift can help prevent electromagnetic interference by maintaining a
minimum distance between portable and mobile RF communications equipment (transmitters) and the
Maxi Twin
lift
by maintaining a distance of not less than 1 meter to any part of the
Maxi Twin
lift, including cables, if the transmitters
output power rating exceeds 1 W.
Guidance and manufacturer’s declaration - electromagnetic immunity
Immunity test
IEC 60601
test level
Compliance
Electromagnetic environment - guidance
Electrostatic
discharge (ESD)
IEC 61000-4-2
6 kVcontact
8 kVair
6 kVcontact
8 kVair
Floors should be wood, concrete or ceramic tile. If floors are
covered with synthetic material, the relative humidity
should be at least 30%.
Radiated RF
IEC 61000-4-3
3 Vrms
80 MHz to
2.5 GHz
10 Vrms
80 MHz to
2.5 GHz
Portable and mobile RF communications equipment should
be used no closer to any part of the
Maxi Twin
lift, including
cables, than 1 meter if the transmitters output power rating
exceeds 1 W
Field strengths from fixed RF transmitters, as determined by
an electromagnetic site survey, A) should be less than the
compliance level in each frequency range. b)
Interference may occur in the vicinity of equipment marked
with the following symbol:
Field strengths from fixed transmitters, such as base stations for radio (cellular/cordless) telephones and land mobile
radios, amateur radio, AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with
accuracy. To assess the electromagnetic environment due to fixed RF transmitters, an electromagnetic site survey
should be considered. If the measured field strength in the location in which the
Maxi Twin
lift is used exceeds the
applicable RF compliance level above, the
Maxi Twin
lift should be observed to verify normal operation. If abnormal
performance is observed, additional measures may be necessary.
b) Over the frequency range 150 kHz to 80 MHz, field strengths should be less than 1 V/m.
Summary of Contents for Maxi Twin
Page 1: ...Maxi Twin with people in mind 04 KT 00_16GB 10 2017 Instructions for Use ...
Page 10: ...10 Loop Bars 2 point Loop Bar Small and Medium 4 point Loop Bar Large ...
Page 11: ...11 Intentionally left blank ...
Page 23: ...23 Intentionally left blank ...
Page 33: ...33 Intentionally left blank ...
Page 37: ...37 Intentionally left blank ...
Page 45: ...45 Intentionally left blank ...