84 /
MENU
SUB-MENU
PARAMETER DESCRIPTION
RANGE
FACTORY SETTINGS
5
5
7
Min T
7°C-MaxT [FC]; 18-MaxT [UFH]
7°C [FC];
18°C [
UFH
]
5
5
8
Target deltaT for pump modulation cooling
[-5; -20°C]
-5°C
12
HYBRID EVO 2 Param
12
0
User Parameters
12
0
0
Hybrid Mode
Auto
Only Boiler
Only HP
Auto
12
0
1
Energy Manager Logic
Max Saving
Max Ecology
Max Ecology
12
0
2
ECO / COMFORT
ECO PLUS
ECO
MEDIO
COMFORT
COMFORT PLUS
MEDIO
12
0
3
AUTO function
Absent
Present
Present
12
0
4
Quiet Mode Activation
OFF - ON
OFF
12
0
5
Quiet Mode start time [hh:mm]
00:00 - 24:00
22:00
12
0
6
Quiet Mode end time [hh:mm]
00:00 - 24:00
06:00
12
0
7
Photovoltaic Integration
Not active
Active
Not active
12
0
8
PV Delta T DHW setpoint temp.
0°C - 20°C
0°C
12
1
Input Output Confi guration
12
1
0
HV Input 1
Not Defi ned
Absent
EDF
SG1
External switch off signal
EDF
12
1
1
HV Input 2
Not Defi ned
Absent
DLSG
SG2
Absent
12
1
2
HV Input 3
Not active
PV Integration Active
Not active
12
1
3
AUX Input 1
None
Humidistat sensor
None
12
1
4
Uscita AUX 1 (AFR)
None
Fault alarm
Humidistat alarm
External heat request
Cooling request
DHW request
None
12
1
5
Uscita AUX 2
None
Fault alarm
Humidistat alarm
External heat request
Cooling request
DHW request
None
12
1
6
AUX P2 circulator setting
Auxiliary circulator
Cooling circulator
Buff er circulator
Auxiliary circulator
12
2
Energy manager parameter 1
12
2
0
Hydraulic scheme
None
WHB Combi
WHB + Tank
None
12
2
1
FlowT HP Off set
2°C - 10°C
2°C
12
2
2
Text for Boiler disabling
Text for HP disabling - 0°C - 40°C
35°C