
/ 79
Graph A (Fan Coil)
Graph B (Underfl oor)
fl
ow temperature to the system
fl
ow temperature to the system
outdoor temperature
outdoor temperature
18
25
33
12
11
10
9
8
7
0
5
10
15
20
25
30
35
40
45
°C
6
°C
23
22
20
21
19
18
0
5
10
15
20
25
30
35
40
45
°C
17
°C
5
10
15
20
25
30
To set the temperature adjustment parameters, simultane-
ously press and hold back “
“ and “OK” buttons until
“Enter code” appears on the display. Turn the knob to en-
ter the technical code (234) then press OK; the display will
show Technical area.
Turn the knob and select
- Complete
Menu.
Press the OK button. Turn the knob and select:
4
ZONE 1 PARAMETERS
4.5 COOLING
4.5.0 T set cool Z1
Press the OK button. Turn the knob and set the delivery
temperature setpoint, for thermoregulation off or fi xed
point.
Press the OK button. Turn the knob and select:
4.5.1
Zone 1 Cooling Temp Range
Press the OK button.
Turn the knob and select the temperature range:
- Fan Coil
- Underfl oor
Press the OK button.
Turn the knob and select:
4.5.2 Thermoregulation
Press the OK button. Turn the knob and set the type of
temperature adjustment installed:
- 0 ON/OFF
- 1 Fix Flow T
- 2 Outdoor T Only
4.5.3 Slope
Press the OK button. Turn the knob and set the curve in
relation to the type of cooling system, then press the OK
button.
- Fan Coil (curves from 18 to 33)
- Underfl oor (curves from 0 to 30)
The checking process for the suitability of the curve re-
quires a long period of time during which several adjust-
ments may be necessary.
When the outdoor temperature rises (summer), three con-
ditions may arise:
1. The temperature of the room may rise, indicating that a
gentler curve should be set;
2. The temperature of the room may fall, indicating that a
steeper curve should be set;
3. The temperature of the room remains constant, indicat-
ing that the set curve is exactly right.
Once you have found the curve which maintains the room
temperature at a constant level, check the actual tempera-
ture value.
IMPORTANT:
If the room temperature is higher than the desired value,
the curve must be shifted downwards decreasing the pam-
eters 4.5.3. If the room temperature is too low, the curve
should be shifted upwards increasing the pameters 4.5.3.
If the temperature of the room corresponds to the desired
value, the curve is correct.
In the graph below, the curves have been divided into two
groups:
- fan coil systems (graph A)
- under-fl oor systems (graph B)
Press the OK button. Turn the knob and select:
4.5.4 Off set
Press the OK button. Turn the knob and set the most suit-
able value. Press the OK button to confi rm.
Turn the knob and select:
4.5.6 Max
T
Press the OK button. Turn the knob and set the most suit-
able value according to zone temperature range (see pa-
rameter 4.5.1), then press the OK button.
Turn the knob and select:
4.5.7 Min
T
Press the OK button. Turn the knob and set the most suit-
able value according to zone temperature range (see pa-
rameter 4.5.1), then press the OK button.
Repeat the steps described to set the values for zones 2
(if present), selecting menu 5.