REMOTE CONTROL DEVICE TECHNICAL DATA
Power supply
BUS
Electrical absorption
max. < 0.5W
Operating temperature
-10 to 60°C
Storage temperature
-20 to 70°C
Bus wire length and cross-sectional area
NOTE: IN ORDER TO AVOID INTERFER-
ENCE PROBLEMS, USE
A SHIELDED CA-
BLE OR TWISTED PAIR CABLE.
max. 50 m
min. 0.5 mm²
Buff er memory
2 h
Conformity
LVD 2006/95/EC - EMC 2004/108/EC
Electromagnetic interference
EN 60730-1
Electromagnetic emissions
EN 60730-1
Conformity to standards
EN 60730-1
Temperature sensor
NTC 5 k 1%
Resolution degree
0.1°C
134 mm
16 mm
96 mm
REMOTE CONTROL DEVICES
OUTDOOR SENSOR
Position the outdoor sensor on the north-facing wall of the
building, at least 2.5 m from the ground and away from
direct sunlight.
Remove the cover (fi g. A) and install the sensor using the
rawl plug and screw provided (fi g. B).
Make the connection using a 2x0.5 mm
2
cable.
Maximum connection length 50 m.
Connect the wire to the terminal (fi g. C) by introducing it
from the lower part after creating a suitable passage.
Place the sensor cover back in the correct position.
A
B
C
PRODUCT FICHE
SUPPLIER’S NAME
ARISTON
SUPPLIER’S MODEL IDENTIFIER
Sensys
Outdoor Sensor
Class of the temperature control
V
II
Contribution to seasonal space heating energy effi
ciency in %
+3%
+2%
Adding an outdoor sensor:
Class of the temperature control
VI
--
Contribution to seasonal space heating energy effi
ciency in %
+4%
--
In a 3-zones system with 2 room sensors
Class of the temperature control
VIII
--
Contribution to seasonal space heating energy effi
ciency in %
+5%
--