37
4.
GAS ADJUSTMENTS
CATEGORY II2H3+
Methane Gas
G20
Liquid Butane Gas
G31
Liquid Propane Gas
G30
Lower Wobbe Index (15°C;1013mbar)
MJ/m
3
h
Nominal Delivery Pressure
mbar
Minimum Delivery Pressure
mbar
45.67
20
20
80.58
29
28
80.58
37
36
0.70
---
2.86 - 0.85
35.6 - 6.8
0.78
---
2.17 - 0.93
36.0 - 7.1
0.78
---
2.45 - 0.93
36.0 - 7.0
0.70
---
1.89 - 0.87
29.0 - 5.5
0.74
---
2.21 - 0.95
27.5 - 5.4
0.74
---
2.48 - 0.95
28.0 - 5.4
1.30
2.54 - 1.16
---
7.5 - 1.7
1.30
2.96 - 1.27
---
9.5 - 1.8
1.30
3.33 - 1.27
---
12.0 - 1.8
microGENUS HE 24 MFFI
Main Burner: n. 14 jets (ø)
mm
Consumption (15°C; 1013mbar) max - min
m
3
/h
Consumption (15°C; 1013mbar) max - min
Kg/h
Gas Burner Pressure
max - min
mbar
microGENUS HE 28 MFFI
Main Burner: n. 14 jets (ø)
mm
Consumption (15°C; 1013mbar) max - min
m
3
/h
Consumption (15°C; 1013mbar) max - min
Kg/h
Gas Burner Pressure
max - min
mbar
microGENUS HE 32 MFFI
Main Burner: n. 14 jets (ø)
mm
Consumption (15°C; 1013mbar) max - min
m
3
/h
Consumption (15°C; 1013mbar) max - min
Kg/h
Gas Burner Pressure
max - min
mbar
The boiler can be converted to use either methane
(natural) gas (G20) or L.P.G. (G30 - G31) by a CORGI
registered Gas Engineer.
The operations that must be performed are the following:
1. Replace the jets on the main burner (see Table A);
2. Adjust the maximum and minimum thermal capacity
values for the boiler
(Section 4.2 Adjusting the Gas
Pressures);
3. Adjust the maximum thermal power setting (
Page 39
and T
ABLE
B 40);
4. Adjust the soft-light feature (see Table opposite for
recommended pressure and Fig. 4.1 see page 39);
5. Adjust the ignition delay feature for the heating system
by adjusting the dip switch as indicated in Section 2.17
(F
IG
. 2.34). It can be turned on or off.
4.1
C
HANGING THE
T
YPE OF
G
AS
CATEGORY
II2H3+
Methane
Gas
G20
Liquid
Butane
Gas
G31
Liquid
Propane
Gas
G30
Soft-light
Pressure (mbar)
24 kW Model
28 kW Model
32 kW Model
5.0
5.5
5.5
12.0
12.0
12.0
12.0
12.0
12.0
T
ABLE
A
S
OFT
L
IGHT
P
RESSURES
Summary of Contents for microGENUS HE 24 MFFI
Page 68: ...68 10 BENCHMARK COMMISSIONING CHECKLIST...
Page 69: ...69 11 SERVICE INTERVAL RECORD...
Page 70: ...70...