61
YES
YES
YES
YES
NO
NO
IS THE
PUMP RUNNING?
1. Check if there is air in
the system
2. Check the main circuit flow
switch operation
3. Check the pressure on the
water gauge and fill system
to 1 bar
1. Check pump cable
2. Check/replace
main P.C.B.
Release/replace
pump
Turn the
ON/OFF button
POWER TO
THE PUMP?
YES
YES
YES
YES
IS
THE LOW WATER
PRESSURE SWITCH
WORKING CORRECTLY?
E02: does not close
NO
NO
NO
NO
A
B
Summary of Contents for microGENUS HE 24 MFFI