49
1. Remove the recuperator - see paragraph. 6.3.8
2. Unscrew the two screws “Y” (F
IG
.6.36);
3. Remove the recuperator housing (F
IG
.6.37);
4. Reassemble in reverse order.
T
HE SIDE COVER OF THE RECUPERATOR MUST NOT BE REMOVED
,
THE TWO SCREWS ARE COVERED BY SECURITY PAINT
,
THERE IS A
DANGER THAT FLUE GASSES COULD LEAK INTO THE ROOM IF THE
FRONT COVER IS REMOVED
.
S
HOULD IT BE NECESSARY TO REMOVE THE RECUPERATOR
,
THE
WHOLE UNIT MUST BE REMOVED
.
6.3.9 Removing the Recuperator Housing
F
IG
. 6.36
Y
Y
F
IG
. 6.37
1. Remove the clamp “Z” (F
IG
.6.38);
2. Remove the clamp “A1” (F
IG
.6.39);
3. Unscrew and remove the trap from the boiler (F
IG
.6.40);
3. Remove the trap (F
IG
.6.41).
4. Reassemble in reverse order
6.3.10 Removing the Condensate Trap
F
IG
. 6.38
Z
F
IG
. 6.39
F
IG
. 6.40
F
IG
. 6.41
A1