16
After removing the boiler from its packaging, remove the
template from the separate box containing the connection
kit. N
OTE
: Pay particular attention to any test water that may
spill from the appliance.
Place the template in the position the appliance is to be
mounted and after ensuring it is hanging squarely, use it to
drill the holes for the hanging bracket, connection kit and
flue pipe(s) NB: For further information relating to the flue
installation please refer to S
ECTION
11 F
LUE
C
ONNECTION
. (If
the appliance is to be fitted on a wall of combustible
material, the wall must be protected by a sheet of fireproof
material).
If the appliance is to be fitted into a timber framed building,
guidance should be sought from the Institute of Gas
Engineers document R
EF
: IGE/UP/7.
10.6.1.
Drill the wall and plug using those supplied with the
connections kit, position the hanging bracket and secure
with the wall bolts supplied, assemble the connection kit and
secure to the wall. N
OTE
: It is highly recommended that a
spirit level be used to position the appliance to ensure that it
is perfectly level.
10.6.2.
Position the appliance on the hanging bracket and
connect the connection kit to the boiler connections. (see
also Sections 10.8 Gas Connections, 10.9 Water
Connections & F
IG
.10.2).
For safety purposes, have a competent person carefully
check the electrical system in the property, as the
manufacturer will not be held liable for damage caused by
the failure to earth the appliance properly or by anomalies in
the supply of power. Make sure that the residential electrical
system is adequate for the maximum power absorbed by the
unit, which is indicated on the rating plate. In addition, check
that the section of cabling is appropriate for the power
absorbed by the boiler.
The boiler operates with alternating current, as indicated in
the Technical Information table (Section 21), where the
maximum absorbed power is also indicated. Make sure that
the connections for the neutral and live wires correspond to
the indications in the diagram. The appliance electrical
connections are situated on the reverse of the control panel
(see the Servicing Instructions Section 18 for further
information).
Important!
In the event that the power supply cord must be changed,
replace it with one with the same specifications. Make the
connections to the terminal board located within the control
panel, as follows:
- The yellow-green wire should be connected to the terminal
marked with the earth symbol; make sure to re-use the
ferrule mounted on the other supply cord;
- The blue wire should be connected to the terminal marked
“N”;
- The brown wire should be connected to the terminal
marked “L”.
Note: The diagrams for the electrical system are indicated in
Section 13.
F
IG
. 10.3
10.7
Electrical Connection
10.6
Mounting the Appliance
Legend:
39 = Gas service tap
40 = Heating return
41 = Heating flow
42 = Water service tap
43 = Tank hot water flow
38 = Water tank valve
44 = Heating valve
F
IG
. 10.2
39
40
41
38
44
42
43
Summary of Contents for GENUS 30 Plus
Page 30: ...30 Airpressure Swi tch Ear th Ear th 13 Electrical System Diagrams FIG 12 4...
Page 62: ...62...