15
10.5
Overall Dimensions
925
500
950
470
195
57
54
145
39
40
41
42
43
38
188
135
80
54
172
54
317
280
44
595
450mm minimum for
servicing purposes
180
F
IG
. 10.1
The type C appliances (in which the combustion circuit,
air vent intake and combustion chamber are air-tight
with respect to the room in which the appliance is
installed) can be installed in any type of room.
Secondary ventilation is not required with this boiler. The
boiler must be installed on a solid, non-combustible,
permanent wall to prevent access from the rear.
In order to allow for access to the interior of the boiler for
maintenance purposes, the boiler must be fitted with a
clearance of 450mm in front 400mm below the boiler and
200mm above the boiler, and installed in compliance with the
clearance requirements indicated in Fig. 10.1.
Legend:
39 = Gas service tap
40 = Heating return
41 = Heating flow
42 = Water service tap
43 = Tank hot water flow
38 = Water tank
discharge valve
44 = Central heating
discharge valve
10.4
Clearances