Subject to change · 40719700 · 1217 · EN
Page 8
www.argo-hytos.com
3. General instructions
For prevention of material damage and product damage
CAUTION
Danger due to improper handling
Property damage
›
The fi lter unit may only be used in accordance with Section 2.2, “Intended use”.
Leakage or spillage of hydraulic fl uid
Environmental pollution and ground water contamination.
›
Use oil binding agents in order to bind leaked hydraulic oil.
Risk of burns
Contact temperatures according to DIN EN563 (3) and DIN EN13202 (4) may be exceed during
operation.
›
Allow the fi lter unit to cool down before touching it.
Contamination due to fl uids and foreign bodies
Premature wear - malfunction - risk of damage - property damage
›
Ensure cleanliness during installation in order to prevent foreign bodies, such as welding beads or metal chips,
from entering the hydraulic lines, leading to premature wear or malfunction.
›
Make sure that connections, hydraulic lines and attachment parts (e.g. gauges) are free of dirt and chips.
›
Prior to commissioning, check that all hydraulic and mechanical connections are connected and tight,
and that all gaskets and seals of the plug connectors are correctly assembled and undamaged.
›
For removal of lubricants and other contaminants, use residue-free industrial wipes.
›
Make sure that all connections, hydraulic lines and attachment parts are clean.
›
Ensure that no contaminants enter when closing the connections.
›
Make sure that no detergents enter the hydraulic system.
›
Do not use cotton waste or faying cleaning rags for cleaning.
›
Do not use hemp as sealing agent.
Improper cleaning
Premature wear - malfunction - risk of damage - property damage
›
Close all openings with appropriate protective fi ttings to prevent penetration of detergents.
›
Do not use aggressive cleaning agents for cleaning. Clean the product with a suitable cleaning fl uid.
›
Do not use a high pressure cleaner.
›
Do not use compressed air to clean function interfaces such as seal areas.