Subject to change · 40719700 · 1217 · EN
Page 15
www.argo-hytos.com
9. Operation
CAUTION
Exposure to spilled oil
Injury / risk of slipping
›
If oil leaks, the oil-covered area must be shut of immediately and covered with an oil binding medium
(risk of slipping).
Static charge
Sparking
›
There is a risk of static charge when using poorly conducting hydraulic or lubricating oils.
In this case, please consult the manufacturer.
NOTE
Damage to the fi lter unit by missing or defective suction strainer.
Property damage.
›
The strainer must be regularly checked according to the maintenance intervals and replaced if necessary.
›
The fi lter unit is provided with a protective strainer at the suction port of the pump. It has to be serviced regularly.
A missing protective strainer may lead to destruction of the pump. (Order No. see spare parts list)
›
If the protective strainer is removed, the manufacturer will resume no liability.
9.1
Filtering hydraulic fl uids when refi lling
1. Connect the fi lter unit to a power source.
2. Place the suction hose into the oil drum.
3. Place the discharge hose into a container (e.g. hydraulic tank).
NOTE
Faulty insertion of the discharge hose
›
Make sure that the discharge hose is below the liquid surface.
4. Turn the fi lter unit on at the ON/OFF switch (circuit breaker).
5. Check the oil fl ow on a possibly insuffi cient immersion depth of the suction hose in the oil tank.
6. Using the clogging indicator, check the element for clogging at operating temperature of the medium used.
7. Check the fi lling level at the machine or system and turn off the fi lter unit at the circuit breaker, once the desired fi lling
quantity has been reached.
8. Clean the hoses and install plugs to their free ends. Re-attach the suction and the discharge hose at the appropriate brackets at
the fi lter unit.
Fig. 7: Filling of the small power pack with the use of the CFP