Subject to change · 40719700 · 1217 · EN
Page 19
www.argo-hytos.com
CAUTION
Risk of burns
Contact temperatures according to DIN EN563 (3) and DIN EN13202 (4) may be exceeded
during operation.
›
No fl uid may pass through the fi lter while the fi lter element is being replaced.
›
Allow the fi lter unit to cool down before touching it.
10.3. Replacing the fi lter element
Turn the fi lter unit off at the ON/OFF switch (circuit breaker) and pull the mains plug.
10.3.1 Removing the fi lter element
1. Unscrew and remove the fi lter cover (1)
2. Carefully remove the sealing ring (2). Check the sealing.
If necessary replace the sealing by new one.
(Order code. of sealing N 031.0562)
3. Remove the fi lter element (3) from the housing.
4. Check the fi lter element type number.
Does the laser inscription on the fi lter element match with
the indications on the type plate or in the operating
manual?
5. Dispose of the fi lter element according to the national
environmental legislation (Waste code: Oil fi lter 16 01 07).
6. Clean the fi lter housing from residual dirt.
7. Carefully insert the new element into the fi lter housing.
8. Install the sealing ring. Check the sealing. If necessary
replace the sealing with new one (order no. of sealing N
031.0562).
9. Screw in the fi lter cover until it stops (use the appropriate
wrench, size 27).
10.3.2 Installing the fi lter element
Fig. 11: Removing the fi lter element
Fig. 12: Installing the fi lter element
3
2
1
7
8
9