93
5. Connect the red tester lead to the yellow/green
wire; then connect the black tester lead to the
orange/white wire.
6. With the starter button depressed, the meter must
show 0 DC volts.
NOTE: If the meter does not show as specified,
replace the switch.
RESISTANCE (Engine Stop Switch)
1. Set the meter selector to the OHMS position.
2. Connect the red tester lead to the orange wire; then
connect the black tester lead to the orange/white wire.
3. With the switch in the OFF position, the meter
must show an open circuit.
4. With the switch in the RUN position, the meter
must show less than 1 ohm.
NOTE: If the meter shows more than 1 ohm of resis-
tance, replace the switch.
RESISTANCE (Reverse Override)
The connector is the four-prong white one next to the
steering post. To access the connector, the front rack and
front fenders must be removed (see Steering/Body/Con-
trols).
1. Set the meter selector to the OHMS position.
2. Connect the red tester lead to one red/yellow wire;
then connect the black tester wire to the other red/yel-
low wire. The meter must show less than 1 ohm.
3. Depress and hold the reverse override button. The
meter must show an open circuit.
4. Connect the red tester lead to the blue wire; then
connect the black meter lead to the black wire. The
meter must show an open circuit.
5. Depress and hold the reverse override button. The
meter must show less than 1 ohm.
NOTE: If the meter does not show as specified,
replace the switch.
Drive Select Switch
The connector is the two-wire black snap-lock one in
front of the steering post. To access the connector, the
cover must be removed.
NOTE: Resistance tests should be made with the
connector disconnected and on the selector-side of
the connector.
RESISTANCE
1. Set the meter selector to the OHMS position.
2. Connect the red tester lead to the red wire; then
connect the black tester lead to the white wire.
3. With the select switch in the 2WD position, the
meter must show an open circuit.
4. With the select switch in the 4WD position, the
meter must show less than 1 ohm.
NOTE: If the meter does not show as specified,
replace the drive select switch.
VOLTAGE
NOTE: The battery must be connected when per-
forming voltage tests.
1. Set the meter selector to the DC Voltage position.
2. Connect the black tester lead to the negative bat-
tery terminal.
3. Connect the red tester lead to the white wire on the
harness side of the connector.
4. Turn the ignition switch to the RUN position.
5. The meter must show 12 DC volts.
NOTE: If the meter shows other than specified,
check the harness, connector, 30 amp fuse, and bat-
tery connections.
Stator Coil
VOLTAGE
(AC Generator - Regulated Output)
1. Set the meter selector to the DC Voltage position.
2. Connect the red tester lead to the positive battery
post; then connect the black tester lead to the nega-
tive battery post.
3. With the engine running at a constant 5000 RPM
(with the headlights on), the meter must show
14-15.5 DC volts.
NOTE: If voltage is lower than specified, test charg-
ing coil - no load.
VOLTAGE (Charging Coil - No Load)
The connector is a three-pin one in the harness coming
from the AC generator.
NOTE: Test the engine-side of the connector.
1. Set the meter selector to the AC Voltage position.
CAUTION
Do not run the engine at high RPM for more than 10 sec-
onds.