2.6. ALARMS
In the event that a malfunction occurs, the board intervenes and signals the irregularities, lighting
the LED alarms (alarm LED on) and beeps.
There are the following alarms:
Origine dell’allarme
Visualizzazione display
Black-out electric power
AL 1 ALAR AL 1 BLAC-OUT
Sensor of flue gas temperature
AL 2 ALAR AL 2 FLUE GAS
Overheting of flue gas
AL 3 ALAR AL 3 HOT EXAUST
Fan Encoder failure
AL 4 ALAR AL 4 FAN FAILURE
No ingition
AL 5 ALAR AL 5 NO LIGHT IN-
No pellet
AL 6 ALAR AL 6 NO PELLET
Overheating of drawer of pellet
AL 7 ALAR AL 7 SAFETY THERMAL
Air pressostat
AL 8 ALAR AL 8 FAILURE DEPRESS-
Each alarm condition causes the immediate shutdown of the stove
The alarm state is reached after about 20 seconds of delay, EXCEPT OF ALARM BLACK-
OUT, and can be reset by pressing and holding the button P3. Whenever resets an alarm,
for safety is initiated a shutdown phase of the stove. During the alarm is always on the
LED alarms (alarm LED illuminated) and enabled when the buzzer will sound
intermittently. If not reset the alarm, the stove will go off in any case, always displaying the
alarm message.
2.6.1 Black-out electricity
During the working status of the stove, may lack electricity. Upon restart, if the period of
the blackout is less than 30 seconds, the stove again mode WORK, otherwise the alarm is
activated. The display will scroll the message "
AL 1 ALAR AL 1 BLAC-OUT
" (Figure 51)
and the stove goes into shutdown.
fig. 51
38
Summary of Contents for AIRPELLET
Page 1: ...TECHNICAL MANUAL AIRPELLET 8 KW 10 KW 12 KW Stoves LIBxxx 56 pag Rev 3 15 01 2013...
Page 2: ......
Page 51: ...12 1 Modulation...
Page 52: ...12 2 Stand by 45...
Page 53: ...12 3 Spegnimento...
Page 60: ...55 Sede legale Via I Maggio 16 46030 S Giorgio Mantova 0376 372206F Fax 0376 374646...
Page 61: ...Produzione Via S Giovanni XXIII 105 26865 S Rocco al Porto LODI 0377 569677 0377 56956...