1.5 Turning on
Before lighting the fire in the stove, carefully
read the instructions for use and
maintenance.
Remove from the pellet storage that is
located under the top cover of the stove,
where is located the display, the components
and documentation that are included in the
packaging, making sure that the deposit is
free from any foreign matter.
Unroll the cable of the ambient sensor which
is placed in the rear of the stove without
placing it on the pieces of the hot stove.
Correctly connect the output of the pellet
stove fumes.Fill the deposit pellet 6 mm in
diameter.
Open the door and check that the grate is
properly inserted into its slot, and that the
seal is properly mounted.
Close the door. Do not open the door until it's
working. Do not open the store until the pellet
stove is operating.Connect the stove with the
appropriate power cord received with the
stove.
Before the first start of the
stove
,
with the dispaly in OFF, select M6
(see par.2.5.7 on page 36) To do this, press
and hold the P1 for about 2 seconds. When
appears the message M1, press the P2
button until appears in the display M6. Then
press P3 to exit the menu M6.
Put the switch at the back of the stove in the
"1" position.
Press the ON / OFF
button
for
2
seconds and the stove will begin its ignition
cycle
For the detailed explanations of the operation
see the chapter 2 “Use and Maintenance” .
fig. 16
15
Summary of Contents for AIRPELLET
Page 1: ...TECHNICAL MANUAL AIRPELLET 8 KW 10 KW 12 KW Stoves LIBxxx 56 pag Rev 3 15 01 2013...
Page 2: ......
Page 51: ...12 1 Modulation...
Page 52: ...12 2 Stand by 45...
Page 53: ...12 3 Spegnimento...
Page 60: ...55 Sede legale Via I Maggio 16 46030 S Giorgio Mantova 0376 372206F Fax 0376 374646...
Page 61: ...Produzione Via S Giovanni XXIII 105 26865 S Rocco al Porto LODI 0377 569677 0377 56956...