4.2.4 Function Relay Outputs
Listed below are other types of functions that can be outputted through the three Function output
relays (K25, K26 and K30). Refer to section 4.2.6.6 ~ 4.2.6.8 function relay programming.
---
:
START function only.
LV
:
Function relay closes when receiver voltage is low.
ID
:
Function relay works simultaneously with all motion commands.
NORMAL :
START fu AUX with normal momentary output.
TOGGLE :
START fu AUX with toggled/latching output.
TOG&E :
START fu AUX with toggled/latching output. The relay opens
when STOP button is pressed down and transmitter power off.
S/P
:
FUNCTION relay closes when START command is executed and opens
only when transmitter power is turned off.
EXT
:
FUNCTION relay works simultaneously with the receiver MAIN relays.
TDM A+B :
FUNCTION relay closes when selector switch is rotated to the A+B
position and opens when rotate to A or B positions (tandem monitoring
output).
HORN
:
FUNCTION relay closes for up to 3 seconds when START command is
initiated at transmitter power on and then becomes normal momentary
outputs thereafter.
G SENSOR :
FUNCTION relay closes when Zero-G sensor is triggered (receiver
MAIN relays deactivated) and opens when receiver MAIN relays are
reactivated.
TANDEM C :
FUNCTION relay closes when tandem receiver C is selected or activated.
RESET
:
FUNCTION relay closes when rotate to START position and opens
when let go. Works during initial transmitter startup and inactivity
timer START reset.
SW8 ABC
:
FUNCTION relay closes at C position (for pushbutton and rotary select ABC
function).
SW12 ABC :
FUNCTION relay closes at C position (for pushbutton and rotary select ABC
function).
4.2.5 Brake Functions
Listed below are types of brake functions with various 1
st
and 2
nd
speed relay actions. Refer to
section 4.2.6.9 brake function programming. For 2-step/speed pushbuttons only.
DEMAG-1 :
When releasing pushbutton from 2
nd
speed up to 1
st
speed, the 1
st
speed output relay will open for up to 1.0 second and then closes again.
DEMAG-2 :
When pushbutton is pressed down to 2
nd
speed directly from 0 speed,
the 1
st
speed output relay will maintain closure for up to 0.4 second
before 2
nd
speed output relay closes. When pushbutton is released from
2
nd
speed up to 0 speed, the 1
st
speed output relay will maintain closure
for up to 0.5 second before going to 0 speed.
DEMAG-3 :
When releasing pushbutton from 2
nd
speed up to 1
st
speed, both 1
st
and
2
nd
speed output relays are opened. Release pushbutton to 0 speed and
then press down to 1
st
speed to reengage the 1
st
speed output relay.
P&H
:
When releasing pushbutton from 2
nd
speed up to 0 speed, the 1
st
speed
output relay will maintain closure for up to 0.1 second before going to 0