Flex EPV Instruction Manual (CE)
April 2020 v1.0
Page 36 of 71
4.2.2.4 None-Interlocking 1 & 2-Step Pushbutton Outputs (Relays)
Non-interlocked setting allows the pushbutton pair be pressed simultaneously. It
usually applies to equipment’s auxiliary functions such as lights, horn or buzzer
(requires 2-step relay module). Refer to section section 4.2.6.10 ~ 4.2.6.15 output
relay programming.
Function #
Function Descriptions (left button / right button)
# of Relays
Used
10000000
Normal / Normal
2
10000010
Normal / Toggled
2
10000110
Normal / Toggled (EMS)**
2
10001000
Normal / Start*
2
10001100
Normal / Pitch & Catch
2
10010000
Toggled / Normal
2
10010010
Toggled / Toggled
2
10010110
Toggled / Toggled (EMS)**
2
10011000
Toggled / Start*
2
10011100
Toggled / Pitch & Catch
2
10110000
Toggled (EMS**) / Normal
2
10110010
Toggled (EMS)** / Toggled
2
10110110
Toggled (EMS)** / Toggled (EMS)**
2
10111000
Toggled (EMS)** / Start*
2
10111100
Toggled (EMS)** / Pitch & Catch
2
11000000
Start* / Normal
2
11000010
Start* / Toggled
2
11000110
Start* / Toggled (EMS)**
2
11001000
Start* / Start*
2
11001100
Start* / Pitch & Catch
2
11100000
Pitch & Catch / Normal
2
11100010
Pitch & Catch / Toggled
2
11100110
Pitch & Catch / Toggled (EMS)**
2
11101000
Pitch & Catch / Start*
2
11111110
4 output relays Closed/Closed relay action at 2
nd
speed
(separate 2
nd
speed output relays)
4
* Start: For added safety, must first rotate and hold the power switch key at the START position
and then press the intended pushbutton to activate the output relay
** EMS: Relay opens when STOP button is pressed down.