Flex EPV Instruction Manual (CE)
April 2020 v1.0
Page 21 of 71
C. Transmitter-to-Receiver Pairing:
JP8 Open Method:
After the transmitter enters the Remote Pairing mode, output transmitter
data by press and hold PB4 on the transmitter and receive data by press and hold the PAIRING
button on the receiver cover, both at the same time. When the transmitter Status LED turns to
constant green while both pushbuttons are still pressed down the pairing is completed. Refer
to section 4.2.3 and section 4.2.6.22 JP8 descriptions and programming.
4.1.4 Transmitter Start Function Settings
When transmitter goes into sleep mode the system is temporarily deactivated (MAIN relays
opened). Execute the START command or press any pushbutton to wake up the system
(MAIN relays closed).
4.1.5 Transmitter Inactivity Timer Settings
Set how long the transmitter enters the sleep mode when not in use (pushbutton not pressed).
When transmitter goes into sleep mode the receiver MAIN relays are deactivated.
Dipswitch
Settings
Time
Dipswitch
Settings
Time
1
xxx
000
xxxx
1 minute
5
xxx
100
xxxx
10 minutes
2
xxx
001
xxxx
20 seconds
6
xxx
101
xxxx
30 minutes
3
xxx
010
xxxx
3 minutes
7
xxx
110
xxxx
60 minutes
4
xxx
011
xxxx
5 minutes
8
xxx
111
xxxx
Constant On
(sleep mode
disabled)
4.1.6 Transmitter Output Power Settings
1mW offers the shortest operating range with lowest battery consumption while 10mW offers
the longest operating range with highest battery consumption (manufacture preset at 2mW).
Dipswitch
Settings
Output
Power
Dipswitch
Settings
Output
Power
1
000
xxxxxxx
1mW
5
100
xxxxxxx
5mW
2
001
xxxxxxx
2mW
6
101
xxxxxxx
6mW
3
010
xxxxxxx
3mW
7
110
xxxxxxx
8mW
4
011
xxxxxxx
4mW
8
111
xxxxxxx
10mW
Dipswitch
Settings
Function
1
xxxxxxxxx
0
START
Reactivation
2
xxxxxxxxx
1
Any Button
Reactivation