Flex EPV Instruction Manual (CE)
April 2020 v1.0
Page 29 of 71
4.1.10 Display Frequency Band
1) Rotate the power switch key to OFF ( 0 ) position.
2) With the STOP button elevated, press and hold PB2 and PB4
at the same time.
3) Rotate the power switch key to ON ( I ) position.
4) Let go PB2 and PB4 at the same time (entered Frequency
Band Display mode).
5) The Status LED displays the preset transmitter frequency band
with orange, green and red blinks. An orange blink represents
the hundreds (+
1
00), a green blink represents the tens (+0
1
0) and a red blink
represents the units (+00
1
). For example,
8
orange blinks followed by
6
green
blinks and
3
red blinks is
8
6
3
MHz.
6) Exit Frequency Band Display mode by rotate the power switch key to OFF ( 0 ) position.
4.1.11 Input and Output Feedback Settings
Up to 4 assignable relay outputs and 4 external inputs can be programmed into the system and
feedback to the transmitter LED indicators during operation. These settings require using the
infrared IR programmer unit. Please contact ARC representative for more details.
4.1.12 Infrared Function Settings
The transmitter is embedded with infrared sensors for infrared start function. These settings
require using the infrared IR programmer unit. Please contact ARC representative for more
details.
4.1.13 Zero-G Sensor Settings
The transmitter is embedded with a Zero-G sensor to guard against any unintended control of
the crane or equipment when transmitter is thrown or dropped. When triggered, the receiver
MAIN relays are deactivated with the exception of the horn output that can be assigned to any
of the Function output relays (K25, K26 or K30). This horn output setting requires the infrared
IR programmer unit. Please contact ARC representative for more details.
Dipswitch
Settings
Function
1
xxxxxxxx
0
x
Sensor Disabled
2
xxxxxxxx
1
x
Sensor Enabled