INSTALLATION
Page 8
DRAIN
We recommend the use of a stand pipe with air trap.
To prevent backflow from the sewerage system into the
water softener, always install and use the included air gap
with double hose barb, to connect the drain hoses to the
sewerage system.
Always use separate drain hoses for the control valve(s)
(evacuation of rinse water) and the brine tank's overflow(s).
Lay-out the drain hoses in such a way that pressure loss
is minimized; avoid kinks and unnecessary elevations.
Make sure that the sewerage system is suitable for the
rinse water flow rate of the water softener.
Picture 7
1.
Install the air gap to the sewerage system; it fits over a
32 mm pipe or inside a 40 mm pipe adaptor. Ensure a
permanent and watertight connection.
2.
Connect a 13 mm hose to the drain elbow of the control
valve (
); secure it by means of a clamp.
3.
Run the drain hose to the air gap and connect it to one of
the hose barbs; secure it by means of a clamp. This drain
line operates under pressure, so it may be installed higher
than the water softener.
4.
Connect a 13 mm hose to the overflow elbow on the brine
tank; secure it by means of a clamp.
5.
Run the drain hose to the air gap and connect it to the
other hose barb. This drain line does NOT operate under
pressure, so it may NOT be installed higher than the water
softener.
6.
For Duplex
: repeat steps 1-3 for both Simplex systems.
For Triplex
: repeat steps 1-5 for all Simplex systems.
ELECTRICAL
Picture 8
1.
Plug the transformers output lead into the socket on the
water softeners power cord; secure it by means of the
TwistLock clamp.
2.
Plug the transformer into an electrical outlet.
DUPLEX/TRIPLEX:
SERVICE VALVES
Picture 9
1.
Plug the DIN plug on the connection cable of the Service
Valve into the DIN socket at the back of the electronic
timer head of the respective control valve (
).
Summary of Contents for ProFlow
Page 1: ...2014 Aquion Inc TM EN ProFlow Rev2014 04 Technical Manual WATER SOFTENER...
Page 18: ...HYDRAULIC FLOW DIAGRAMS Page 18 SERVICE BACKWASH BRINE DRAW SLOW RINSE FAST RINSE REFILL...
Page 19: ...Page 19...
Page 26: ...EXPLODED VIEW SIMPLEX TEMPO ECO Page 26...
Page 28: ...EXPLODED VIEW DUPLEX ECO ALTERNATING Page 28...
Page 30: ...EXPLODED VIEW DUPLEX ECO PARALLEL Page 30...
Page 32: ...EXPLODED VIEW TRIPLEX ECO PARALLEL Page 32...
Page 34: ...EXPLODED VIEW TIMER HEAD SIMPLEX Page 34...
Page 36: ...EXPLODED VIEW TIMER HEAD DUPLEX ALTERNATING Page 36...
Page 38: ...EXPLODED VIEW TIMER HEAD DUPLEX TRIPLEX PARALLEL Page 38...
Page 40: ...EXPLODED VIEW VALVE BODY Page 40...
Page 45: ...2013 Aquion Inc PP ProFlow Rev2014 01 r 1 2 a 2 b 3 a 3 b...
Page 46: ...2013 Aquion Inc PP ProFlow Rev2014 01 r 4 a 4 b r 5 a 5 b...
Page 47: ...2013 Aquion Inc PP ProFlow Rev2014 01 6 7 a 7 b r 8 a 8 b...
Page 48: ...2013 Aquion Inc PP ProFlow Rev2014 01 r 9 10 r 11 r 12...
Page 49: ...2013 Aquion Inc PP ProFlow Rev2014 01 13 14 a 14 b 14 c...
Page 50: ...2013 Aquion Inc PP ProFlow Rev2014 01 15...