TROUBLESHOOTING
Page 21
PROBLEM
CAUSE
SOLUTION
Control valve fails to
refill brine tank
Improper refill time setting
Verify that refill time corresponds to salt level and
amount of resin
Plugged refill flow control
Clean refill flow control
Loss of resin
Lower and/or upper distributor damaged
Replace distributor(s)
Leak between riser tube and upper distributor
Verify that riser tube is seated correctly and is not
cracked
Control valve fails to
draw brine
Low operating pressure
Check operating pressure; must be higher than 1,4
bar
Plugged injector
Clean injector
Restricted drain line
Verify drain line for kinks or restrictions
Restricted brine line
Verify brine line for kinks or restrictions
Leak in brine line
Verify brine line and connections for air leakage
No water in brine tank
Refer to problem “Control valve fails to refill brine
tank”
Control valve cycles
continuously
Defective micro switch
Replace micro switches
Duplex/Triplex Parallel:
all Simplex systems
regenerate
simultaneously
InterConnect communication does not
function correctly
Check connections of InterConnect cable(s)
Defective PCB
Replace PCB
Duplex Alternating:
both Simplex systems
are in service
simultaneously
InterConnect communication does not
function correctly
Check connections of InterConnect cable
Defective PCB
Replace PCB
Defective Service Valve
Replace Service Valve
Summary of Contents for ProFlow
Page 1: ...2014 Aquion Inc TM EN ProFlow Rev2014 04 Technical Manual WATER SOFTENER...
Page 18: ...HYDRAULIC FLOW DIAGRAMS Page 18 SERVICE BACKWASH BRINE DRAW SLOW RINSE FAST RINSE REFILL...
Page 19: ...Page 19...
Page 26: ...EXPLODED VIEW SIMPLEX TEMPO ECO Page 26...
Page 28: ...EXPLODED VIEW DUPLEX ECO ALTERNATING Page 28...
Page 30: ...EXPLODED VIEW DUPLEX ECO PARALLEL Page 30...
Page 32: ...EXPLODED VIEW TRIPLEX ECO PARALLEL Page 32...
Page 34: ...EXPLODED VIEW TIMER HEAD SIMPLEX Page 34...
Page 36: ...EXPLODED VIEW TIMER HEAD DUPLEX ALTERNATING Page 36...
Page 38: ...EXPLODED VIEW TIMER HEAD DUPLEX TRIPLEX PARALLEL Page 38...
Page 40: ...EXPLODED VIEW VALVE BODY Page 40...
Page 45: ...2013 Aquion Inc PP ProFlow Rev2014 01 r 1 2 a 2 b 3 a 3 b...
Page 46: ...2013 Aquion Inc PP ProFlow Rev2014 01 r 4 a 4 b r 5 a 5 b...
Page 47: ...2013 Aquion Inc PP ProFlow Rev2014 01 6 7 a 7 b r 8 a 8 b...
Page 48: ...2013 Aquion Inc PP ProFlow Rev2014 01 r 9 10 r 11 r 12...
Page 49: ...2013 Aquion Inc PP ProFlow Rev2014 01 13 14 a 14 b 14 c...
Page 50: ...2013 Aquion Inc PP ProFlow Rev2014 01 15...