POH / AFM
AQUILA AT01-100C
SECTION 3
EMERGENCY PROCEDURES
Document Nr.:
Issue:
Supersedes Issue:
Date:
Page:
FM-AT01-1010-103
A.08
A.06 (01.06.2018)
25.05.2020
3 - 13
3.10.3 Low Voltage Indication
A) On the ground (voltmeter values YELLOW or RED)
1.
Engine speed
Increase RPM until value turns
GREEN (RPM should be below
1350)
2.
All non-essential equipment
OFF, until value turns GREEN.
3.
If the value remains YELLOW or RED
Do not fly before problem is
eliminated.
B)
In flight
Voltmeter value YELLOW
1.
All non-essential equipment
OFF, until value turns GREEN
2.
If the value remains YELLOW
Alternator is defective.
Proceed in accordance with
section 3.10.2
Voltmeter value RED
1.
Value RED
Alternator is defective.
Proceed in accordance with
section 3.10.2
C)
During approach and landing (voltmeter value YELLOW or RED)
1.
After landing
Proceed in accordance with
paragraph 3.10.3 A)
WARNING
If, at any point, the voltmeter value turns RED, land at the nearest airfield and solve the
problem before continuing flight.