POH / AFM
AQUILA AT01-100C
SECTION 3
EMERGENCY PROCEDURES
Document Nr.:
Issue:
Supersedes Issue:
Date:
Page:
FM-AT01-1010-103
A.08
A.06 (01.06.2018)
25.05.2020
3 - 12
3.10 ELECTRICAL SYSTEM MALFUNCTIONS
3.10.1 Complete Electrical System Failure
1.
ALT1 / BAT
switch
CHECK if ON
2.
BAT1
circuit breaker
(see 3.1.1)
RESET if tripped
3.
ALT1
circuit breaker
(see 3.1.1)
RESET if tripped
If power cannot be restored, it is recommended to carry out a precautionary landing at the
nearest airfield.
3.10.2 Alternator Failure (ALT1)
Warning light
ENG
(RED) with ammeter values shown in RED and/or
ALT1
warning light is
illuminated
1.
ALT1
switch
SWITCH OFF then ON, approx. 10 sec.
interval
2.
ALT1
circuit breaker
(see 3.1.1)
RESET if tripped
If
ALT1
warning light remains illuminated:
3.
ALT1
circuit breaker
PULL
4.
ALT1
SWITCH
OFF
5. Instruments not required for the safe continuation of flight should be turned off or dimmed to
at least half the intensity.
6. Monitor the voltmeter and ammeter
7. Land at the nearest airfield.
NOTE
A fully charged and properly serviced battery will be able to supply power to all essential
systems for approx. 30 minutes.
Even with the audio panel turned off the pilot can still transmit with COM 1 (Failsafe Design) via
his headset. Use of the Intercom is not possible.
WARNING
Before returning the aircraft to service, the problem must be resolved.