background image

2

Contents

1. Operational parameters .................................................................................. 3
2. Safety instructions ........................................................................................... 4
3. Product assembly ............................................................................................ 5
4. RO design and operation principles  ........................................................... 6
5. RO installation .................................................................................................. 7
6. Clean water faucet installation  .................................................................... 8
7. Drain saddle installation ................................................................................. 9
8. Slotted plug installation ............................................................................... 10
9. Starting RO ...................................................................................................... 10
10. Replacing cartridges..................................................................................... 11
11. Recommended filter replacement  .............................................................12
12. Recommended filter maintenance ............................................................12
13. Warranty  .........................................................................................................13
14. Troubleshooting ............................................................................................14

Summary of Contents for RO-101S

Page 1: ...AQUAPHOR RO 101S RO 102S RO 101S EU RO 102S EU RO 101S IL RO 102S IL in further RO REVERSE OSMOSIS SYSTEM OWNER S MANUAL...

Page 2: ...d operation principles 6 5 RO installation 7 6 Clean water faucet installation 8 7 Drain saddle installation 9 8 Slotted plug installation 10 9 Starting RO 10 10 Replacing cartridges 11 11 Recommended...

Page 3: ...atically rinsed away through the drain leaving you with only high quality delicious water for your use 1 Operational parameters Operating temperatures Maximum 38 C 100 4 F Minimum 5 C 41 F Operating p...

Page 4: ...installing the appliance into a local water supply it is recommended that you conduct a full water analysis If the water analysis does not correspond with the requirements the life of the filtration...

Page 5: ...phor RO 102S Aquaphor RO 101S IL 5 1 pc Replacement filter cartridge K7B for Aquaphor RO 101S EU Aquaphor RO 102S EU Aquaphor RO 102S IL 5 3 JG connecting tubes 6 JG tube 3 8 d 9 5 mm 1 pc JG tube 1 4...

Page 6: ...unds non organic compounds and salts while sof tening water Water conditioning block 5 includes the min eralizing cartridge K7M for RO 101S RO 102S Aquaphor RO 101S IL or K7BM for RO 101S EU RO 102S E...

Page 7: ...Take care to ensure that the de livery tubes are pulled freely without over bend ing RO must be installed on a flat even solid surface as installation on an uneven surface may cause vibration or nois...

Page 8: ...ng O Ring is located correctly in its place and not damaged during installation Connection of JG tubes Pull the locking clip 2 off the plastic plug 1 Then install the previously wetted end of the tube...

Page 9: ...he drain saddle on most drain pipes is of 40 mm diameter 1 Apply the part of the collar with the fitting to the pipe to determine the optimal position of the collar and the pipe hole 2 Drill a 7 mm ho...

Page 10: ...s Cartridge type BLACK K2 BLUE 5 1 RED Service Cap WHITE 7 7 Make sure the service cap is installed in the housing Remove the shrink film from the cartridges Rinse the sealing O Rings of the cartridge...

Page 11: ...ssure 2 Press the button above the cartridge and then rotate the used filter cartridges 5 1 and or K2 in a clockwise direction to remove the used cartridge 3 Install the new cartridges 5 1 and or K2 a...

Page 12: ...rtridge and the resulting loss of sealing of the RO connections it is not recom mended to dissemble it without a fully qualified maintenance specialist If the RO connections are leaking immediately cl...

Page 13: ...maintains the correct drinking water salt balance You should replace the post filter every 6 months 13 Warranty Installation operational storage and transpor tation rules described in this manual sho...

Page 14: ...com pletely opened Open the shutoff valve and faucet completely One of the replacement cartridges needs to be replaced Checkwhichcartridgeneedstobereplacedaccord ing to the resource life and replace t...

Page 15: ...O at aquaphor com register for manufacturer s warranty Installation information Installation is carried out Name of the company which carried out installation Name of the service engineer Service engi...

Page 16: ...r date of manufacture and quality control are shown on the product s serial number label The manufacturer reserves the right to make improvements to the design of the water purifier withoutreflecting...