AQUAPHOR RO-101S Owner'S Manual Download Page 7

7

When the clean water faucet is opened, water 
from the mains enters the technical chamber 
via the shutoff valve and forces treated water 
from the storage chamber through the faucet 

via the conditioning block. The automatic check 
valve then triggers and opens water supply to 
the RO-storage tank.

5. RO installation

 ATTENTION! 

 Only install your RO by a qualified 

plumber who is certified to perform the instal-
lation in accordance with state law.   
Locate the appropriate installation place for the 
faucet and RO. Take care to ensure that the de-
livery tubes are pulled freely, without over bend-
ing. RO must be installed on a flat, even solid 
surface as installation on an uneven surface may 
cause vibration or noise. Additionally, RO must 
be located away from heat sources, such as 
kitchen ovens, hot water supply pipes, dishwash-
ers or washing machines, or at least isolated 
from such heat sources. 

Water flow direction

Kitchen

faucet

Clean water 

faucet

RO housing

Drain saddle

Cold water 

supply 

Drain water

JG tube 1/4”

Connection node, 

shutoff valve 

in open position 

Incoming tap 

water JG 

tube 3/8” 

Treated water

JG tube 1/4”

Picture 4.

 RO installation scheme

How RO works

The water coming from the cold water mains 
enters RO and passes through the preliminary 
water treatment block. From there, water enters 
the Reverse Osmosis membrane block via the 
automatic check valve. The unit housing the 
membrane cartridge has two outlets: the treated 
water outlet and the drain water outlet. On its 
way to the drain, the water will also pass through 
a flow restrictor. The flow restrictor flushes the 
drain water that goes down the drain.
The treated water enters the storage tank that 
has a built-in membrane. This separates the tank 
into two chambers: storage and technical. The 
storage chamber contains the fully purified drink-
ing water, while the technical chamber contains 
water from the mains. As clear water collects, 
water from the mains is forced from the techni-
cal chamber into the drain, also preventing the 
accumulation of clear water. When the storage 
tank is full, the automatic check valve cuts off 
the water intake into RO.

Reverse 

Osmosis 

membrane

Incoming 

tap water

Pressure

Treated water

Summary of Contents for RO-101S

Page 1: ...AQUAPHOR RO 101S RO 102S RO 101S EU RO 102S EU RO 101S IL RO 102S IL in further RO REVERSE OSMOSIS SYSTEM OWNER S MANUAL...

Page 2: ...d operation principles 6 5 RO installation 7 6 Clean water faucet installation 8 7 Drain saddle installation 9 8 Slotted plug installation 10 9 Starting RO 10 10 Replacing cartridges 11 11 Recommended...

Page 3: ...atically rinsed away through the drain leaving you with only high quality delicious water for your use 1 Operational parameters Operating temperatures Maximum 38 C 100 4 F Minimum 5 C 41 F Operating p...

Page 4: ...installing the appliance into a local water supply it is recommended that you conduct a full water analysis If the water analysis does not correspond with the requirements the life of the filtration...

Page 5: ...phor RO 102S Aquaphor RO 101S IL 5 1 pc Replacement filter cartridge K7B for Aquaphor RO 101S EU Aquaphor RO 102S EU Aquaphor RO 102S IL 5 3 JG connecting tubes 6 JG tube 3 8 d 9 5 mm 1 pc JG tube 1 4...

Page 6: ...unds non organic compounds and salts while sof tening water Water conditioning block 5 includes the min eralizing cartridge K7M for RO 101S RO 102S Aquaphor RO 101S IL or K7BM for RO 101S EU RO 102S E...

Page 7: ...Take care to ensure that the de livery tubes are pulled freely without over bend ing RO must be installed on a flat even solid surface as installation on an uneven surface may cause vibration or nois...

Page 8: ...ng O Ring is located correctly in its place and not damaged during installation Connection of JG tubes Pull the locking clip 2 off the plastic plug 1 Then install the previously wetted end of the tube...

Page 9: ...he drain saddle on most drain pipes is of 40 mm diameter 1 Apply the part of the collar with the fitting to the pipe to determine the optimal position of the collar and the pipe hole 2 Drill a 7 mm ho...

Page 10: ...s Cartridge type BLACK K2 BLUE 5 1 RED Service Cap WHITE 7 7 Make sure the service cap is installed in the housing Remove the shrink film from the cartridges Rinse the sealing O Rings of the cartridge...

Page 11: ...ssure 2 Press the button above the cartridge and then rotate the used filter cartridges 5 1 and or K2 in a clockwise direction to remove the used cartridge 3 Install the new cartridges 5 1 and or K2 a...

Page 12: ...rtridge and the resulting loss of sealing of the RO connections it is not recom mended to dissemble it without a fully qualified maintenance specialist If the RO connections are leaking immediately cl...

Page 13: ...maintains the correct drinking water salt balance You should replace the post filter every 6 months 13 Warranty Installation operational storage and transpor tation rules described in this manual sho...

Page 14: ...com pletely opened Open the shutoff valve and faucet completely One of the replacement cartridges needs to be replaced Checkwhichcartridgeneedstobereplacedaccord ing to the resource life and replace t...

Page 15: ...O at aquaphor com register for manufacturer s warranty Installation information Installation is carried out Name of the company which carried out installation Name of the service engineer Service engi...

Page 16: ...r date of manufacture and quality control are shown on the product s serial number label The manufacturer reserves the right to make improvements to the design of the water purifier withoutreflecting...

Reviews: