8. Slotted plug installation

1.  Install the slotted plug into the JG tube 

3/8” (9.5 mm) tube to a stop, as shown  
on figure 10. 

2.  Remove the clip from the JG tube 3/8” socket 

of the water filter, and then connect this tube 
end to it (see the connection of the JG tubes 
on figures 6 and 7).

 ATTENTION! 

 The set includes three slotted 

plugs: one for installation and two are for 
spares. 

9. Starting RO

To start RO, you must connect the supply tube 
and carry out the flushing procedure of filter 
and  membrane cartridges.

Step 1

Connect the incoming tubes according to the 

diagram below (figure 11). The tube connection 

scheme is illustrated on figure 6

Step 2

Preparing RO for operation

• Rotate the three latches 90 degrees in a coun-

terclockwise direction and remove the water 
filter cap (figure 2).

Table 2. Positions of RO cartridges  
in preparation for operation

Stop button colors 

Cartridge type

BLACK

K2

BLUE

К5 / К1

RED

Service Cap

WHITE

К7М / К7ВМ

• Make sure the service cap is installed in the 

housing. 

• Remove the shrink film from the cartridges.  
• Rinse the sealing O-Rings of the cartridges 

and service cap.

• Remove service caps and install cartridgies 

according to table 2. For convenience, the 
stop buttons of the collectors have the dif-
ferent color. 

• Set the shutoff valve on the connection node 

into the open position, as shown on figure 4.

• Leave the clean water faucet open for 

10 minutes.

The noise during the flushing of the cartridges 

is not a defect.

• Close the clean water faucet.  

Step 3

Flushing the membrane cartridge unit  

• Set the shutoff valve on the connection node 

into the closed position, as shown on figure 5.

• Remove the service plug and install membrane 

cartridge.

• Interchange the К5 / К1 and K2 cartridges.
• Turn the shutoff valve on the connection node 

into the open position.  

• Open the clean water faucet, then wait for the 

water to start flowing.  

Figure 10.

 Slotted plug installation

Slotted plug

Figure 11. Incoming tubes connection

IN

OUT DRAIN

Summary of Contents for RO-101S

Page 1: ...AQUAPHOR RO 101S RO 102S RO 101S EU RO 102S EU RO 101S IL RO 102S IL in further RO REVERSE OSMOSIS SYSTEM OWNER S MANUAL...

Page 2: ...d operation principles 6 5 RO installation 7 6 Clean water faucet installation 8 7 Drain saddle installation 9 8 Slotted plug installation 10 9 Starting RO 10 10 Replacing cartridges 11 11 Recommended...

Page 3: ...atically rinsed away through the drain leaving you with only high quality delicious water for your use 1 Operational parameters Operating temperatures Maximum 38 C 100 4 F Minimum 5 C 41 F Operating p...

Page 4: ...installing the appliance into a local water supply it is recommended that you conduct a full water analysis If the water analysis does not correspond with the requirements the life of the filtration...

Page 5: ...phor RO 102S Aquaphor RO 101S IL 5 1 pc Replacement filter cartridge K7B for Aquaphor RO 101S EU Aquaphor RO 102S EU Aquaphor RO 102S IL 5 3 JG connecting tubes 6 JG tube 3 8 d 9 5 mm 1 pc JG tube 1 4...

Page 6: ...unds non organic compounds and salts while sof tening water Water conditioning block 5 includes the min eralizing cartridge K7M for RO 101S RO 102S Aquaphor RO 101S IL or K7BM for RO 101S EU RO 102S E...

Page 7: ...Take care to ensure that the de livery tubes are pulled freely without over bend ing RO must be installed on a flat even solid surface as installation on an uneven surface may cause vibration or nois...

Page 8: ...ng O Ring is located correctly in its place and not damaged during installation Connection of JG tubes Pull the locking clip 2 off the plastic plug 1 Then install the previously wetted end of the tube...

Page 9: ...he drain saddle on most drain pipes is of 40 mm diameter 1 Apply the part of the collar with the fitting to the pipe to determine the optimal position of the collar and the pipe hole 2 Drill a 7 mm ho...

Page 10: ...s Cartridge type BLACK K2 BLUE 5 1 RED Service Cap WHITE 7 7 Make sure the service cap is installed in the housing Remove the shrink film from the cartridges Rinse the sealing O Rings of the cartridge...

Page 11: ...ssure 2 Press the button above the cartridge and then rotate the used filter cartridges 5 1 and or K2 in a clockwise direction to remove the used cartridge 3 Install the new cartridges 5 1 and or K2 a...

Page 12: ...rtridge and the resulting loss of sealing of the RO connections it is not recom mended to dissemble it without a fully qualified maintenance specialist If the RO connections are leaking immediately cl...

Page 13: ...maintains the correct drinking water salt balance You should replace the post filter every 6 months 13 Warranty Installation operational storage and transpor tation rules described in this manual sho...

Page 14: ...com pletely opened Open the shutoff valve and faucet completely One of the replacement cartridges needs to be replaced Checkwhichcartridgeneedstobereplacedaccord ing to the resource life and replace t...

Page 15: ...O at aquaphor com register for manufacturer s warranty Installation information Installation is carried out Name of the company which carried out installation Name of the service engineer Service engi...

Page 16: ...r date of manufacture and quality control are shown on the product s serial number label The manufacturer reserves the right to make improvements to the design of the water purifier withoutreflecting...

Reviews: