8

Connection node assembly
• Turn the water off at the cold water main.
• Open the kitchen faucet to discharge pressure 

into the water line.  

• Unscrew the nut from the flexible line cap, 

leading to the faucet on the cold water main. 

 ATTENTION! 

 Residual water will be left inside 

of the flexible JG tube after discharge of water.   
When disconnecting the flexible line, please use 
a 200 ml or similar size container to drain the 
water left behind in the tube.
• Screw the cap nut off the connection node and 

on the cold water main thread.

• Screw the cap nut off the flexible line, and then 

on the connection node thread.

• Set the shutoff valve on the connection node 

to the closed position and then make sure that 
the connection is completely leak-proof by sup-
plying water to the cold water main. 

• Connect JG tube (follow the instructions below 

to correctly connect the JG tubes). 

 ATTENTION! 

 Make sure that the sealing O-Ring 

is located correctly in its place and not damaged 
during installation.

Connection of JG tubes

Pull the locking clip (2) off the plastic plug (1). 
Then install the previously wetted end of the 
tube (3) into the fitting piece approx.15 mm up 
to the stop. Next, put the locking clip (2) back. 

Make sure that the tube (3) is tightened correctly: 
the tube should not be pulled out by force greater 
than 8-10 kgf.

Disconnection of JG tubes

Pull the locking clip (2) off the plastic plug (1), 
then pull the tube (3) out by applying pressure 
on the face of the connecting piece. To apply 
pressure, use the tube disconnection key (4) 
included in the water filter set.

6. Clean water faucet 
installation 

• Drill the hole in the sink (table top) 12 mm 

diameter;

• Put on the thread tail of the faucet (11) rubber 

gasket (2), decorative stand (3), rubber gasket 
(4) and insert the faucet into the hole in the sink;

Figure 5. 

Connection node installation scheme

Connection 

node

Sealing 

O-Ring

Cold water main

Locking clip 

Shutoff valve set 

in closed position

Figure 6. 

Connection of JG tubes

3

2

1

Figure 7. 

Disconnection of JG tubes

3

2

1

Summary of Contents for RO-101S

Page 1: ...AQUAPHOR RO 101S RO 102S RO 101S EU RO 102S EU RO 101S IL RO 102S IL in further RO REVERSE OSMOSIS SYSTEM OWNER S MANUAL...

Page 2: ...d operation principles 6 5 RO installation 7 6 Clean water faucet installation 8 7 Drain saddle installation 9 8 Slotted plug installation 10 9 Starting RO 10 10 Replacing cartridges 11 11 Recommended...

Page 3: ...atically rinsed away through the drain leaving you with only high quality delicious water for your use 1 Operational parameters Operating temperatures Maximum 38 C 100 4 F Minimum 5 C 41 F Operating p...

Page 4: ...installing the appliance into a local water supply it is recommended that you conduct a full water analysis If the water analysis does not correspond with the requirements the life of the filtration...

Page 5: ...phor RO 102S Aquaphor RO 101S IL 5 1 pc Replacement filter cartridge K7B for Aquaphor RO 101S EU Aquaphor RO 102S EU Aquaphor RO 102S IL 5 3 JG connecting tubes 6 JG tube 3 8 d 9 5 mm 1 pc JG tube 1 4...

Page 6: ...unds non organic compounds and salts while sof tening water Water conditioning block 5 includes the min eralizing cartridge K7M for RO 101S RO 102S Aquaphor RO 101S IL or K7BM for RO 101S EU RO 102S E...

Page 7: ...Take care to ensure that the de livery tubes are pulled freely without over bend ing RO must be installed on a flat even solid surface as installation on an uneven surface may cause vibration or nois...

Page 8: ...ng O Ring is located correctly in its place and not damaged during installation Connection of JG tubes Pull the locking clip 2 off the plastic plug 1 Then install the previously wetted end of the tube...

Page 9: ...he drain saddle on most drain pipes is of 40 mm diameter 1 Apply the part of the collar with the fitting to the pipe to determine the optimal position of the collar and the pipe hole 2 Drill a 7 mm ho...

Page 10: ...s Cartridge type BLACK K2 BLUE 5 1 RED Service Cap WHITE 7 7 Make sure the service cap is installed in the housing Remove the shrink film from the cartridges Rinse the sealing O Rings of the cartridge...

Page 11: ...ssure 2 Press the button above the cartridge and then rotate the used filter cartridges 5 1 and or K2 in a clockwise direction to remove the used cartridge 3 Install the new cartridges 5 1 and or K2 a...

Page 12: ...rtridge and the resulting loss of sealing of the RO connections it is not recom mended to dissemble it without a fully qualified maintenance specialist If the RO connections are leaking immediately cl...

Page 13: ...maintains the correct drinking water salt balance You should replace the post filter every 6 months 13 Warranty Installation operational storage and transpor tation rules described in this manual sho...

Page 14: ...com pletely opened Open the shutoff valve and faucet completely One of the replacement cartridges needs to be replaced Checkwhichcartridgeneedstobereplacedaccord ing to the resource life and replace t...

Page 15: ...O at aquaphor com register for manufacturer s warranty Installation information Installation is carried out Name of the company which carried out installation Name of the service engineer Service engi...

Page 16: ...r date of manufacture and quality control are shown on the product s serial number label The manufacturer reserves the right to make improvements to the design of the water purifier withoutreflecting...

Reviews: