AQUAPHOR RO-101S Owner'S Manual Download Page 12

12

Replacing the conditioning  
cartridge K7M / К7ВМ 

1.  Set the shutoff valve on the connection node 

into the closed position; then open the clean 
water faucet to discharge pressure.

2.  Press the button above the cartridge, and then 

rotate the used conditioning cartridge K7M / 
К7ВМ in a clockwise direction to remove it.

3.  Install a new conditioning cartridge.
4.  Set the shutoff valve on the connection node 

into the open position; then wait for all of 
the water to flow out from the storage tank 
through the clean water faucet.

5.  Then close the clean water faucet.
6.  When the tank is filled, your RO is ready for 

operation. 

7.  Make sure that RO is properly sealed.

Replacing the membrane 
cartridge

1.  Set the shutoff valve on the connection node 

into the closed position, and then open the 
clean water faucet to discharge pressure. 

2.  Press the button above the cartridge, and 

then rotate the used membrane cartridge 
in a clockwise direction to remove it.

3.  Install a new membranecartridge in place of 

the removed one.

4.  Turn the shutoff valve on the connection node 

to the open position.  

5.  Flush the water through RO for duration of 

approximately 1 hour.*

6.  Close the clean water faucet. 
7.  When the tank is filled, RO is ready for 

operation.

8.  Make sure that RO is properly sealed.

 ATTENTION! 

 To avoid any incorrect installation 

of the membrane cartridge and the resulting loss 
of sealing of the RO connections, it is not recom-
mended to dissemble it without a fully qualified 
maintenance specialist. If the RO connections 
are leaking, immediately close the tap on the 

* Depending upon storage, transportation and operation con-
ditions, complete flushing of the membrane cartridge may take 
up to 24 hours.

connection unit and check the cartridges for 
correct installation.

11. Recommended filter 
replacement 

The frequency at which the filter and membrane 
cartridges should be replaced depends on the 
quality of the water that enters the appliance. 
Contact your water treatment specialist for re-
placement filters and parts.

 NOTE: 

 The installation of the RO appliance on 

a pre-treated water supply will greatly increase 
the life of its filters.

Table 3. Recommended filter 
replacement

Filter Cartridges

Recommended 

Replace ment 

(months)

Replacement filter cartridge 
К5 / К1 (1)

Replacement filter cartridge 
K2 (2)

Replacement membrane car-
tridge RO-50S / RO-100S (3)

12 

Replacement filter cartridge 
K7M (4)

12

Replacement filter cartridge 
K7BM (4)

6

Once purchased, the cartridges can be stored 
for three years from the manufacturing date. 

12. Recommended filter 
maintenance

The frequency at which the filter and membrane 
cartridges should be replaced depends on your 
tap water quality. 
Note: Any filter that demonstrates reduced water 
production or a slower rate of flow is likely to be 
overdue for a change.

 WARNING: 

 Shut off the water to the appliance 

before beginning any maintenance work.

Summary of Contents for RO-101S

Page 1: ...AQUAPHOR RO 101S RO 102S RO 101S EU RO 102S EU RO 101S IL RO 102S IL in further RO REVERSE OSMOSIS SYSTEM OWNER S MANUAL...

Page 2: ...d operation principles 6 5 RO installation 7 6 Clean water faucet installation 8 7 Drain saddle installation 9 8 Slotted plug installation 10 9 Starting RO 10 10 Replacing cartridges 11 11 Recommended...

Page 3: ...atically rinsed away through the drain leaving you with only high quality delicious water for your use 1 Operational parameters Operating temperatures Maximum 38 C 100 4 F Minimum 5 C 41 F Operating p...

Page 4: ...installing the appliance into a local water supply it is recommended that you conduct a full water analysis If the water analysis does not correspond with the requirements the life of the filtration...

Page 5: ...phor RO 102S Aquaphor RO 101S IL 5 1 pc Replacement filter cartridge K7B for Aquaphor RO 101S EU Aquaphor RO 102S EU Aquaphor RO 102S IL 5 3 JG connecting tubes 6 JG tube 3 8 d 9 5 mm 1 pc JG tube 1 4...

Page 6: ...unds non organic compounds and salts while sof tening water Water conditioning block 5 includes the min eralizing cartridge K7M for RO 101S RO 102S Aquaphor RO 101S IL or K7BM for RO 101S EU RO 102S E...

Page 7: ...Take care to ensure that the de livery tubes are pulled freely without over bend ing RO must be installed on a flat even solid surface as installation on an uneven surface may cause vibration or nois...

Page 8: ...ng O Ring is located correctly in its place and not damaged during installation Connection of JG tubes Pull the locking clip 2 off the plastic plug 1 Then install the previously wetted end of the tube...

Page 9: ...he drain saddle on most drain pipes is of 40 mm diameter 1 Apply the part of the collar with the fitting to the pipe to determine the optimal position of the collar and the pipe hole 2 Drill a 7 mm ho...

Page 10: ...s Cartridge type BLACK K2 BLUE 5 1 RED Service Cap WHITE 7 7 Make sure the service cap is installed in the housing Remove the shrink film from the cartridges Rinse the sealing O Rings of the cartridge...

Page 11: ...ssure 2 Press the button above the cartridge and then rotate the used filter cartridges 5 1 and or K2 in a clockwise direction to remove the used cartridge 3 Install the new cartridges 5 1 and or K2 a...

Page 12: ...rtridge and the resulting loss of sealing of the RO connections it is not recom mended to dissemble it without a fully qualified maintenance specialist If the RO connections are leaking immediately cl...

Page 13: ...maintains the correct drinking water salt balance You should replace the post filter every 6 months 13 Warranty Installation operational storage and transpor tation rules described in this manual sho...

Page 14: ...com pletely opened Open the shutoff valve and faucet completely One of the replacement cartridges needs to be replaced Checkwhichcartridgeneedstobereplacedaccord ing to the resource life and replace t...

Page 15: ...O at aquaphor com register for manufacturer s warranty Installation information Installation is carried out Name of the company which carried out installation Name of the service engineer Service engi...

Page 16: ...r date of manufacture and quality control are shown on the product s serial number label The manufacturer reserves the right to make improvements to the design of the water purifier withoutreflecting...

Reviews: