Setting up
• Do not place the appliance in direct sunlight or near cookers,
radiators and similar sources of heat.
• The floor on which the appliance stands should be horizontal and
level. Compensate for uneven floors with the adjustable feet.
• Do not cover ventilation openings or grille.
• Always install the appliance directly against the
wall.
• Standard EN 378 specifies that the room in
which you install your appliance must have
a volume of 1 m
3
per 8 g of R 600a refriger-
ant used in the appliance, so as to avoid the
formation of inflammable gas/air mixtures in
the room where the appliance is located in
the event of a leak in the refrigerant circuit.
The quantity of refrigerant used in your appliance is indicated on
the type plate on the inside of the appliance.
Appliance dimensions
A B C D E
TC 135 S
850 mm 600 mm 600 mm 648 mm 1153 mm
TC 255 S
1640 mm 600 mm 610 mm 650 mm 1180 mm
TC 445 S
1640 mm 750 mm 730 mm 850 mm 1410 mm
Installing beneath a worktop TC 135 S
For continuous worktops the refrigerator‘s tabletop can be detached.
The refrigerator can then be pushed under the existing worktop.
• To take off tabletop remove screws
➊
.
• A cross-section of min. 200 cm
2
is re quired in the worktop
for ventilation of the rear of the appliance.
Electrical connection
Only operate the appliance with
alternating current (AC)
.
The permissible voltage and frequency are indicated on the type plate.
The socket must be properly earthed and protected by a fuse.
The tripping current of the fuse must be between 10 A and 16 A.
The socket must not be situated behind the appliance
and must be easily accessible.
Do not connect the appliance using an exten-
sion cable or extension socket.
Do not use stand-alone inverters (conversion of
direct current to alternating current/three-phase
current) or energy-saving plugs. Risk of damage
to the electronic control system!
Safety lock TC 135 S
The lock in the appliance door is equipped with a safety mechanism.
Locking the appliance
• Insert the key as shown
by arrow
1
.
• Turn the key 90°.
To unlock the appliance, the
same procedure must be re-
peated in the same order.
Safety lock TC 255 S, TC 445 S
The lock in the appliance door is
equipped with a safety mechanism.
Locking the appliance
• Insert the key as shown by
arrow
1
.
• Turn the key 90°.
To unlock the appliance, the same
procedure must be repeated in the
same order.
Important
TC 135 S, TC 255 S
The maximum load per grid shelf is 45 kg.
TC 445 S
The maximum load per grid shelf is 60 kg.
Important
When unpacking and setting up use protective gloves.
Summary of Contents for TC 135 S
Page 9: ...TC 135 S TC 255 S TC 445 S_4 02 2019 9 DE...
Page 17: ...TC 135 S TC 255 S TC 445 S_4 02 2019 17 GB...
Page 25: ...TC 135 S TC 255 S TC 445 S_4 02 2019 25 FR...
Page 33: ...TC 135 S TC 255 S TC 445 S_4 02 2019 33 ES...
Page 41: ...TC 135 S TC 255 S TC 445 S_4 02 2019 41 PT...
Page 42: ...TC 135 S TC 255 S TC 445 S_4 02 2019 42...