![Aqualisa Visage Installation Manual Download Page 8](http://html1.mh-extra.com/html/aqualisa/visage/visage_installation-manual_2960112008.webp)
Visage™ Digital Installation Guide 8
CONTROLLERS - CONCEALED SHOWER
Positioning the controller
Think about the location of the controller. Avoid grout lines where possible to ensure
good surface contact with the silicone seal of the mounting plate. Choose a suitable
height so all users can easily see and use the controller.
Ensure the data cable is the correct way round as both ends differ in type of connection
used (transparent connector to the Quartz Smart Valve™).
Data cables must be protected by suitable sheathing or conduit in the event of servicing
and maintenance. Failure to install this way will invalidate the warranty.
Care should be taken to ensure that fixings do not pierce the data cable conduit.
If the supplied screws are not suitable for the mounting surface, use a screw of the same
size and head design, the screws used must be non corrosive.
Power supply to the Quartz Smart Valve™ must be switched off before connecting or
removing the controller.
Unscrew the two front cover fixings at the base of the controller,
ensuring the captive screws drop sufficiently to allow the front
cover to be pulled clear. Carefully lift the controller from the
bottom of the back plate and pull the cover clear.
2
Place the back plate on the wall in the desired location for the
controller and mark all fixing points and the data cable entry
point. Remove the back plate and drill a Ø16mm hole at the
appropriate position for the data cable.
Ensure the data cable is the correct way round as both ends differ in type of connection
used (transparent connector to the Quartz Smart Valve™).
Data cables must be protected by suitable sheathing or conduit in the event of servicing
and maintenance. Failure to install this way may invalidate the warranty.
Care should be taken to ensure the mounting holes do not pierce the data cable conduit.
1