Visage™ Digital Installation Guide  3

IMPORTANT INFORMATION

Safety information

This appliance can be used by children aged 

from 3 years and above and persons with 

reduced physical, sensory or mental capabilities 

or lack of experience and knowledge if they 

have been given supervision or instruction 

concerning use of the appliance in a safe way 

and understand the hazards involved. Children 

shall not play with the appliance.

Cleaning and user maintenance shall not be 

made by children without supervision.

This product must be installed by a competent 

person in accordance with all relevant current 

local and national Water Supply Regulations.

ALL PRODUCTS REQUIRING AN ELECTRICAL 

CONNECTION MUST BE INSTALLED BY 

A QUALIFIED PERSON FOLLOWING THE 

LATEST REVISION OF THE ELECTRICAL 

WIRING REGULATIONS, BOTH NATIONAL 

AND LOCAL AND CERTIFIED TO CURRENT 

BUILDING REGULATIONS.

This system should be installed so that other 

taps or appliances operated elsewhere within 

the premises do not significantly affect the 

flow. The Quartz Smart Valve™ must not be 

used with a hot water supply temperature 

of over 65ºC. If the maximum hot water 

temperature is likely to rise above 65ºC then 

a Thermostatic Blending Valve must be used. 

The Quartz Smart Valve™ is supplied factory 

pre-set at maximum temperature of 45ºC. The 

maximum temperature is fully adjustable to suit 

site conditions. If adjusted, we recommend the 

outlet temperature is set to a MAXIMUM of 

46ºC. 

The Quartz Smart Valve™ must be installed 

in an accessible location for servicing and 

maintenance. The Quartz Smart Valve™ must 

not be installed in situations where either the 

ambient temperature is likely to exceed 40ºC or 

where freezing may occur. The controller must 

not be installed in situations where the ambient 

temperature is likely to fall below 5ºC or rise 

above 40ºC.

We do not recommend the use of a controller 

in steam therapy facilities. This appliance must  

 

be earthed. Cables must be protected by a 

suitably sized conduit or trunking to avoid risk 

of damage and to allow removal for service and 

maintenance purposes. Failure to install this way 

may invalidate the warranty.

Ensure that the conduit is run to avoid the 

controller fixing holes.

Surface mounted cables must also be protected 

by a suitable approved conduit, even in a loft, 

where there may be a risk of damage from 

vermin.

The power lead must only be replaced by the 

manufacturer or their accredited agent. The 

controller is supplied from a safety low voltage 

source. This product is suitable for domestic use 

only. 

Installation of the pumped Quartz Smart 

Valve™ (for gravity stored systems)

The pumped Quartz Smart Valve™ shower 

system is designed to operate up to a 

maximum static pressure of 100kPa 

((1 bar)(10 metres head)(14.5psi)). Under no 

circumstances must the pumped Quartz Smart 

Valve™ be connected directly to the water 

main or in line with another booster pump. 

The minimum actual capacity of the cold water 

storage cistern should be not less than 225 

litres (50 gallons). The capacity of the hot water 

cylinder must be capable of meeting anticipated 

demand.

Installation of the standard (unpumped) 

Quartz Smart Valve™ (for balanced 

high pressure and unvented systems, 

combination boiler systems and 

separately pumped gravity systems)

Pressures: The standard (unpumped) Quartz 

Smart Valve™ is designed to operate up to a 

maximum static pressure of 700kPa ((7 bar)

(100psi)). Where pressures are likely to exceed 

700kPa ((7 bar)(100psi)), a pressure reducing 

valve must be fitted to the incoming mains 

supply. A setting of 400kPa ((4 bar)(60psi)) is 

recommended. It should be noted that daytime 

pressures approaching 600kPa ((6 bar)(80psi)) 

can rise above the stated maximum overnight.

Summary of Contents for Visage

Page 1: ...VISAGE DIGITAL INSTALLATION GUIDE...

Page 2: ...de 2 CONCEALED COMPONENTS 1 2 EXPOSED COMPONENTS 1 1 Gravity stored water systems only 2 Mains fed and separately pumped water systems only 2 1 Gravity stored water systems only 2 Mains fed and separa...

Page 3: ...ituations where the ambient temperature is likely to fall below 5 C or rise above 40 C We do not recommend the use of a controller in steam therapy facilities This appliance must be earthed Cables mus...

Page 4: ...ED PUMP Shower Heads The range of shower heads has been designed for use with Smart systems Installation of any shower heads other than these may result in poor shower performance If at any stage duri...

Page 5: ...sited it may interfere with digital TV reception Please follow the recommendations below to minimise this effect See recommended layouts below Images of Quartz Smart Valve for illustration only refer...

Page 6: ...operation and installation of this product the Quartz diverter MUST be installed in one of the orientations shown PLEASE NOTE If installing a diverter please also note all areas ma For installation wi...

Page 7: ...e to the mounting surface using the screws provided if suitable 4 Attach the supply pipes to the Quartz Smart Valve ensuring that the cold and hot feeds are fitted into the appropriately marked inlets...

Page 8: ...ign the screws used must be non corrosive Power supply to the Quartz Smart Valve must be switched off before connecting or removing the controller Unscrew the two front cover fixings at the base of th...

Page 9: ...le plug into the back of the controller ensuring both rubber skirts are recessed into the connection see diagram below using a blunt flat bladed screwdriver or similar tool if required To make a water...

Page 10: ...truction please ensure the entry hole is neat and unobtrusive otherwise the inner tube could be visible within the showering area Remove ceiling plate if required DO NOT use a compression fitting or s...

Page 11: ...acket over the rail and support pillar and mark the fixing points Remove the fixing bracket and drill and prepare the fixing points using the fixings provided if suitable Secure the bracket to the wal...

Page 12: ...kirts are recessed into the connection see diagram below using a blunt flat bladed screwdriver or similar tool if required To make a water tight fitting ensure the rubber seal is no longer visible 12...

Page 13: ...hat these are located in an accessible dry location and not in the bathroom 1 THIS APPLIANCE MUST BE EARTHED We recommend protecting surface mounted cables in suitable approved conduit to avoid the ri...

Page 14: ...default Standard Quartz Smart Valve Combi Factory default will be Normal HP this setting must be changed to Combi for temperature stability and optimum performance Balanced High Pressure Standard Quar...

Page 15: ...allation Guide 15 Wiring Diagram Single Outlet BLENDED WATER COLD HOT 3AMP FUSED ELECTRICAL CONNECTION 10m CABLE 10m CABLE CONTROLLER WIRED REMOTE supplied separately Cables must be run in conduit or...

Page 16: ...lve Using a flat bladed screwdriver adjust the MAX TEMP ADJUSTMENT control as indicated When the temperature has been set to the desired position carefully replace the Quartz Smart Valve lid and secur...

Page 17: ...spacer fitting 2 Trim the projecting pipe to a length of 15 22mm measured from the face of the gripper ring using a suitable cutter If a hacksaw is used the pipe end must be carefully de burred and c...

Page 18: ...he single release button of the handset holder and slide onto the rail assembly 11 Carefully slide the gel hook onto the rail under the handset holder 12 Secure the top rail bracket into position on t...

Page 19: ...must be passed through the gel hook which has been designed to be utilised as a hose restraint Disengage the pivot clip and remove the pivot from the bottom of the handset Ensure the hose washer is in...

Page 20: ...e Supply Hot water cylinder Connect A or B Cold feed to cylinder B A NB THE BASE OF THE AQUALISA SMARTVALVETM MUST BE SITED NO HIGHER THAN THE BASE LEVEL OF THE CISTERN Central heating boiler Supply U...

Page 21: ...max Controller 10m max 10m max Controller Underside of cistern Supply Pressure reducing valve if required Central heating boiler Supply Supply Underside of cistern Hot water cylinder Cold feed to cyli...

Page 22: ...e temperature dial to the required setting 1 Press the Start Stop button on the controller to turn the shower on 2 The temperature may be adjusted whilst in the shower 4 The LED display will flash unt...

Page 23: ...reduce the need for chemical descaling in hard water areas your shower head incorporates a clear flow system whereby any scale build up can be broken down by gently rubbing the flexible tips of the j...

Page 24: ...the dial towards the hottest setting Isolate hot and cold feeds to the Quartz Smart Valve disconnect from the inlet spigots and then using the isolation valve bleed through the hot and cold supplies R...

Page 25: ...on Logic Module of Quartz Smart Valve If hot water supply is from a combination boiler the Logic module mode MUST be set to COMBI Airlock in water supplies for gravity fed systems only See Air lock in...

Page 26: ...es enquiries 01 864 3363 Service enquiries 01 844 3212 Aqualisa International Jan Palfijnstraat 26 002 Kortrijk Belgium 8500 Part No 705521 Issue 01 Mar 21 Please note that calls may be recorded for t...

Reviews: