CONTROLLER COMMISSIONING INSTRUCTIONS
Reinstate the electrical supply to the Quartz Smart Valve™. Press the ‘Start/Stop’ button on
the controller to turn the shower on.
4
Turn on the power supply to the Quartz Smart Valve™.
1
Run the shower at maximum temperature (factory pre set to 45ºC). If required, the maximum
temperature can be adjusted. (Refer to Safety Information for guidance).
2
To adjust the maximum temperature, isolate the power supply to
the Quartz Smart Valve™.
Using a flat bladed screwdriver adjust the ‘MAX TEMP
ADJUSTMENT’ control as indicated. When the temperature has
been set to the desired position, carefully replace the Quartz
Smart Valve™ lid and secure the fixing screw, hand tight only.
3
When the power supply to the Quartz Smart Valve™ is turned on the controller will
automatically go into a set-up/configuration sequence.
Whilst in the set-up sequence the controller LED will flash, this process can take up to 2
minutes to complete.
The controller is ready to use once the configuration process has finished.
For concealed products, fit the shower head system following the section: Adjustable
Height Heads.
For exposed products proceed to point 18