18
Commissioning – Dream concealed
The Dream concealed valve is pre-set to a safe maximum shower temperature. During use, the action of the stop
button may be overridden by depressing it as the temperature control is rotated. Should it be necessary to reset
the maximum temperature position please observe the following procedures.
1. Ensure that the hot water system is at normal maximum temperature.
2. Turn the temperature control lever to the full cold position (9 o’clock).
3. Carefully remove the on/off control lever and set aside.
4. Loosen the grub screw within the on/off knob using the hexagonal key provided and pull the knob clear.
5. Remove the temperature control lever screws and pull the lever clear.
6. Carefully remove the coloured pre-set override ring and re-set in the appropriate direction to increase
(clockwise) or decrease (anti-clockwise) the temperature where the override button needs to be pressed.
7. Depress the stop button and replace the temperature lever in the full cold position. Push the on/off knob into
position fully home, but do not secure with the grub screw at this stage.
8. Test the shower by turning it on and slowly increasing the temperature, at the selected point, the button
should pop up and prevent further movement.
9. Repeat the above process if the maximum temperature stop button needs further adjustment.
10. Follow steps 20 to 22 on page 12 to re-fit the temperature lever and on/off knob.
Should the on/off knob need to be removed at any time, turn the knob fully off with the lever pointing in
the 12 o’clock position. Unscrew the lever and set aside. Insert a 2.5mm hexagonal key into the lever fixing
position and loosen the grub screw to enable the knob to be pulled clear.
Dream installation guide:Dolphin install Guide 18/1/11 09:52 Page 18