Smartlog
- 38 -
Click “Next” to continue.
The next screen allows you to configure the flow rate interpolation table and alerts.
Graphic representation of the table
Choice of the unit used for the table
Height/flow rate interpolation table
Add/Delete a point on the table*
Confirm/Cancel the input
Save/Open an interpolation table
Activating alerts
Alert threshold
* maximum 32 points
Click “Next” to continue.
The next screen allows you to configure the storage period.
Setting the storage period*
(must be between 2 min and 60 min)
Enabling a period of quick storage, used
when the overflow sensor is active.
Setting the period of quick storage (used
during overflows)
(must be between 2 min and 60 min)
* If the option “different acquisition period during overflows”
is not checked this storage period will be used permanently.